Oh yeah. ...well the Puls ones we use have a cooler color...so there ...ha On Dec 16, 2015 8:09 PM, "Sam Lambie" <[email protected]> wrote:
> I have been using the SDR120-48's on our Backhauls for over a year now and > none have failed. Knock on wood... I wanted to see if anyone else was using > the 24's with success. > > > On Wed, Dec 16, 2015 at 4:01 PM, Lewis Bergman <[email protected]> > wrote: > >> We hadn't any issue with the din rail mwanwell's we used. >> >> On Wed, Dec 16, 2015, 3:34 PM Jaime Solorza <[email protected]> >> wrote: >> >>> hope they hold up for you...I only know of Meanwell from users on list. >>> >>> >>> Jaime Solorza >>> Wireless Systems Architect >>> 915-861-1390 >>> >>> On Wed, Dec 16, 2015 at 2:25 PM, Sam Lambie <[email protected]> >>> wrote: >>> >>>> For now, I am going with the Meanwells. The Puls are out of our budget >>>> at the moment. Thanks for the info Jaime. >>>> >>>> On Wed, Dec 16, 2015 at 2:18 PM, Jaime Solorza < >>>> [email protected]> wrote: >>>> >>>>> i did mention to Sam I Am that the Puls are pricey.....as are Phoenix >>>>> Contact.....he could use Idec...acceptable lower cost.... >>>>> >>>>> Jaime Solorza >>>>> Wireless Systems Architect >>>>> 915-861-1390 >>>>> >>>>> On Wed, Dec 16, 2015 at 1:20 PM, George Skorup <[email protected]> >>>>> wrote: >>>>> >>>>>> I still have many sites on regular old AC UPS's and AC-DC DIN rail >>>>>> power supplies plugged into them. Works fine, until the UPS takes a shit. >>>>>> Then I just convert to a DC UPS. That's the nice thing with the Traco >>>>>> BCMU360, you can keep your existing power supply, as long as it's enough >>>>>> to >>>>>> run the load + 12-15W for maintaining the battery. >>>>>> >>>>>> But anyway, I used a lot of Phoenix Contact TRIO power supplies (like >>>>>> 20+) and only one ever died because it was hit with 13kV when the primary >>>>>> came down on top of the secondaries feeding the building. :( Those are >>>>>> pretty expensive, so I started buying Mean Well SDR120-24's and so far >>>>>> those have been working without an issue. >>>>>> >>>>>> You can't go wrong with an industrial power supply, as long as it >>>>>> isn't a POS. I consider most Mean Well stuff to be pretty cheap, but >>>>>> they've proven to not be garbage. >>>>>> >>>>>> On 12/16/2015 1:35 PM, Josh Baird wrote: >>>>>> >>>>>> Traco TSP series. If you need battery backup, throw in a BCM module. >>>>>> >>>>>> On Wed, Dec 16, 2015 at 2:22 PM, Sam Lambie <[email protected]> >>>>>> wrote: >>>>>> >>>>>>> Who is using what and why? >>>>>>> The power supplies that Packetflux sells, seems to burn out after >>>>>>> about a year at the most inconvenient times. I am looking for something >>>>>>> more robust. >>>>>>> Currently, I am using Meanwell SDR120-48 for the bigger devices >>>>>>> (Backhauls and 430 AP's) but am looking for something a bit more >>>>>>> reliable >>>>>>> in 24vdc. >>>>>>> >>>>>>> -- >>>>>>> -- >>>>>>> *Sam Lambie* >>>>>>> Taosnet Wireless Tech. >>>>>>> 575-758-7598 Office >>>>>>> www.Taosnet.com <http://www.newmex.com> >>>>>>> >>>>>> >>>>>> >>>>>> >>>>> >>>> >>>> >>>> -- >>>> -- >>>> *Sam Lambie* >>>> Taosnet Wireless Tech. >>>> 575-758-7598 Office >>>> www.Taosnet.com <http://www.newmex.com> >>>> >>> >>> > > > -- > -- > *Sam Lambie* > Taosnet Wireless Tech. > 575-758-7598 Office > www.Taosnet.com <http://www.newmex.com> >