Enclosure + outdoors + SS + grounding lug
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Wed, Jan 13, 2016 at 2:43 PM, Josh Reynolds <[email protected]> wrote: > LOL $500? > > I was using these: http://www.monoprice.com/product?p_id=10039 > > On Wed, Jan 13, 2016 at 1:22 PM, Josh Luthman <[email protected] > > wrote: > >> Another box between electronics and AP, that might be a good idea. What >> compression fittings? >> >> If I do a patch panel/punch blocks it'll be with this: >> http://www.mccowntech.com/gige-twr-outdoor-tower-wall-mount-ethernet-surge-suppressor-protector/ >> My concern would be if water did get in the line, would it ruin that box? >> >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Wed, Jan 13, 2016 at 2:18 PM, Josh Reynolds <[email protected]> >> wrote: >> >>> Drew u a pic >>> >>> AP --------------------cat5--------------------compression >>> fitting-----[box]-----service loop-----shielded patch >>> panel-----[/box][conduit]--------------------[/conduit][shack]-----service >>> loop-----shielded patch panel-----shielded patch cable-----switch/router >>> >>> On Wed, Jan 13, 2016 at 1:06 PM, Josh Luthman < >>> [email protected]> wrote: >>> >>>> Maybe another way to put it is after you terminate the run, what do you >>>> plug in to? Going straight to RJ45ecs is a mess and going straight to the >>>> SS wouldn't be very cable management friendly and potentially ruin SS every >>>> time water finds it's way in, causing more problems. >>>> >>>> >>>> Josh Luthman >>>> Office: 937-552-2340 >>>> Direct: 937-552-2343 >>>> 1100 Wayne St >>>> Suite 1337 >>>> Troy, OH 45373 >>>> >>>> On Wed, Jan 13, 2016 at 2:01 PM, Mike Hammett <[email protected]> wrote: >>>> >>>>> Why are you going into the connector? Terminate the cable and that's >>>>> the end of it. >>>>> >>>>> >>>>> (Do you see what I did there?) :-) >>>>> >>>>> >>>>> >>>>> ----- >>>>> Mike Hammett >>>>> Intelligent Computing Solutions >>>>> http://www.ics-il.com >>>>> >>>>> <https://www.facebook.com/ICSIL> >>>>> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb> >>>>> <https://www.linkedin.com/company/intelligent-computing-solutions> >>>>> <https://twitter.com/ICSIL> >>>>> >>>>> Midwest Internet Exchange >>>>> http://www.midwest-ix.com >>>>> >>>>> <https://www.facebook.com/mdwestix> >>>>> <https://www.linkedin.com/company/midwest-internet-exchange> >>>>> <https://twitter.com/mdwestix> >>>>> ------------------------------ >>>>> *From: *"Josh Luthman" <[email protected]> >>>>> *To: *[email protected] >>>>> *Sent: *Wednesday, January 13, 2016 12:54:40 PM >>>>> *Subject: *Re: [AFMUG] Terminating cable at the base of the tower >>>>> >>>>> >>>>> Sure. >>>>> >>>>> I have a bunch of APs, BHs, cameras, etc on the tower with cat5/rj45. >>>>> Those come down the tower. What do you terminate to? How do you organize >>>>> them? I prefer terminating to rj45 and not a punch block, but maybe that >>>>> would be better if the general consensus goes that way. >>>>> >>>>> My problem now is that going into an rj45ecs is nearly impossible to >>>>> open up when you can't get your fingers around all of it, so when there >>>>> are >>>>> many tightly done together you're screwed. >>>>> >>>>> >>>>> Josh Luthman >>>>> Office: 937-552-2340 >>>>> Direct: 937-552-2343 >>>>> 1100 Wayne St >>>>> Suite 1337 >>>>> Troy, OH 45373 >>>>> >>>>> On Wed, Jan 13, 2016 at 1:52 PM, Josh Reynolds <[email protected]> >>>>> wrote: >>>>> >>>>>> I'm not sure I understand your question... >>>>>> >>>>>> Can you explain things a bit better? >>>>>> >>>>>> On Wed, Jan 13, 2016 at 12:50 PM, Josh Luthman >>>>>> <[email protected]> wrote: >>>>>> > We've been using RJ45ECS for a while but on sites with many (>6) >>>>>> aps this >>>>>> > presents a problem if we need to get to the cable. After some >>>>>> frost bite, I >>>>>> > gave up and just cut the cable to reterminate it. I'd like to have >>>>>> a better >>>>>> > solution for 1 and many runs. >>>>>> > >>>>>> > What has worked for you guys when winter comes around and you need >>>>>> access to >>>>>> > the cables? >>>>>> > >>>>>> > Josh Luthman >>>>>> > Office: 937-552-2340 >>>>>> > Direct: 937-552-2343 >>>>>> > 1100 Wayne St >>>>>> > Suite 1337 >>>>>> > Troy, OH 45373 >>>>>> >>>>> >>>>> >>>>> >>>> >>> >> >