Enclosure + outdoors + SS + grounding lug

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Wed, Jan 13, 2016 at 2:43 PM, Josh Reynolds <[email protected]> wrote:

> LOL $500?
>
> I was using these: http://www.monoprice.com/product?p_id=10039
>
> On Wed, Jan 13, 2016 at 1:22 PM, Josh Luthman <[email protected]
> > wrote:
>
>> Another box between electronics and AP, that might be a good idea.  What
>> compression fittings?
>>
>> If I do a patch panel/punch blocks it'll be with this:
>> http://www.mccowntech.com/gige-twr-outdoor-tower-wall-mount-ethernet-surge-suppressor-protector/
>>  My concern would be if water did get in the line, would it ruin that box?
>>
>>
>> Josh Luthman
>> Office: 937-552-2340
>> Direct: 937-552-2343
>> 1100 Wayne St
>> Suite 1337
>> Troy, OH 45373
>>
>> On Wed, Jan 13, 2016 at 2:18 PM, Josh Reynolds <[email protected]>
>> wrote:
>>
>>> Drew u a pic
>>>
>>> AP --------------------cat5--------------------compression
>>> fitting-----[box]-----service loop-----shielded patch
>>> panel-----[/box][conduit]--------------------[/conduit][shack]-----service
>>> loop-----shielded patch panel-----shielded patch cable-----switch/router
>>>
>>> On Wed, Jan 13, 2016 at 1:06 PM, Josh Luthman <
>>> [email protected]> wrote:
>>>
>>>> Maybe another way to put it is after you terminate the run, what do you
>>>> plug in to?  Going straight to RJ45ecs is a mess and going straight to the
>>>> SS wouldn't be very cable management friendly and potentially ruin SS every
>>>> time water finds it's way in, causing more problems.
>>>>
>>>>
>>>> Josh Luthman
>>>> Office: 937-552-2340
>>>> Direct: 937-552-2343
>>>> 1100 Wayne St
>>>> Suite 1337
>>>> Troy, OH 45373
>>>>
>>>> On Wed, Jan 13, 2016 at 2:01 PM, Mike Hammett <[email protected]> wrote:
>>>>
>>>>> Why are you going into the connector? Terminate the cable and that's
>>>>> the end of it.
>>>>>
>>>>>
>>>>> (Do you see what I did there?)   :-)
>>>>>
>>>>>
>>>>>
>>>>> -----
>>>>> Mike Hammett
>>>>> Intelligent Computing Solutions
>>>>> http://www.ics-il.com
>>>>>
>>>>> <https://www.facebook.com/ICSIL>
>>>>> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb>
>>>>> <https://www.linkedin.com/company/intelligent-computing-solutions>
>>>>> <https://twitter.com/ICSIL>
>>>>>
>>>>> Midwest Internet Exchange
>>>>> http://www.midwest-ix.com
>>>>>
>>>>> <https://www.facebook.com/mdwestix>
>>>>> <https://www.linkedin.com/company/midwest-internet-exchange>
>>>>> <https://twitter.com/mdwestix>
>>>>> ------------------------------
>>>>> *From: *"Josh Luthman" <[email protected]>
>>>>> *To: *[email protected]
>>>>> *Sent: *Wednesday, January 13, 2016 12:54:40 PM
>>>>> *Subject: *Re: [AFMUG] Terminating cable at the base of the tower
>>>>>
>>>>>
>>>>> Sure.
>>>>>
>>>>> I have a bunch of APs, BHs, cameras, etc on the tower with cat5/rj45.
>>>>> Those come down the tower.  What do you terminate to?  How do you organize
>>>>> them?  I prefer terminating to rj45 and not a punch block, but maybe that
>>>>> would be better if the general consensus goes that way.
>>>>>
>>>>> My problem now is that going into an rj45ecs is nearly impossible to
>>>>> open up when you can't get your fingers around all of it, so when there 
>>>>> are
>>>>> many tightly done together you're screwed.
>>>>>
>>>>>
>>>>> Josh Luthman
>>>>> Office: 937-552-2340
>>>>> Direct: 937-552-2343
>>>>> 1100 Wayne St
>>>>> Suite 1337
>>>>> Troy, OH 45373
>>>>>
>>>>> On Wed, Jan 13, 2016 at 1:52 PM, Josh Reynolds <[email protected]>
>>>>> wrote:
>>>>>
>>>>>> I'm not sure I understand your question...
>>>>>>
>>>>>> Can you explain things a bit better?
>>>>>>
>>>>>> On Wed, Jan 13, 2016 at 12:50 PM, Josh Luthman
>>>>>> <[email protected]> wrote:
>>>>>> > We've been using RJ45ECS for a while but on sites with many (>6)
>>>>>> aps this
>>>>>> > presents a problem if we need to get to the cable.  After some
>>>>>> frost bite, I
>>>>>> > gave up and just cut the cable to reterminate it.  I'd like to have
>>>>>> a better
>>>>>> > solution for 1 and many runs.
>>>>>> >
>>>>>> > What has worked for you guys when winter comes around and you need
>>>>>> access to
>>>>>> > the cables?
>>>>>> >
>>>>>> > Josh Luthman
>>>>>> > Office: 937-552-2340
>>>>>> > Direct: 937-552-2343
>>>>>> > 1100 Wayne St
>>>>>> > Suite 1337
>>>>>> > Troy, OH 45373
>>>>>>
>>>>>
>>>>>
>>>>>
>>>>
>>>
>>
>

Reply via email to