Why not use the the ePMP PtP/AP Lite for an SM? It's not much more than a regular SM and it can be powered the same as the APs.
On Mon, Feb 1, 2016 at 4:58 PM, Adam Moffett <[email protected]> wrote: > If Steve is wondering: The a lot of Meanwell PSU's have a screw to adjust > the output voltage. Usually it's to match the float voltage of batteries, > but if you don't have batteries you can crank it up all the way. > > > > On 2/1/2016 4:29 PM, Josh Baird wrote: > > We have gone back to sites and cranked the PSU's feeding the SyncInjectors > up to ~30V. We had numerous power and sync problems in the cold weather > when our PSU's were outputting ~25-26V (there was ~150ft of cable to the > radio as well). We'll be rolling 48V at all future sites. > > On Mon, Feb 1, 2016 at 4:25 PM, Brandon Yuchasz <[email protected]> > wrote: > >> I have run all mine at 24 volts all winter without issue. I did not have >> any of the cold susceptible mac addresses however. My only concern is if >> had a long power outage and batteries died perhaps the epmp would have >> powered up the heaters and never got to boot. It did not happen so it’s >> simply a theory on what could still go wrong for me this winter. I do plan >> to step those packetflux units up to 29.5v soon as possible. >> >> >> >> >> >> Best regards, >> >> Brandon Yuchasz >> >> GogebicRange.net >> >> <http://www.gogebicrange.net/>www.gogebicrange.net >> >> >> >> *From:* Af [mailto:[email protected]] *On Behalf Of *Mike Hammett >> *Sent:* Monday, February 01, 2016 3:04 PM >> *To:* [email protected] >> *Subject:* Re: [AFMUG] Packetflux gigabit syncinjector force >> connectorized epmp 24 V >> >> >> >> Running them at 24v is what some of the commotion has been about lately. >> >> >> >> ----- >> Mike Hammett >> Intelligent Computing Solutions <http://www.ics-il.com/> >> <https://www.facebook.com/ICSIL> >> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb> >> <https://www.linkedin.com/company/intelligent-computing-solutions> >> <https://twitter.com/ICSIL> >> Midwest Internet Exchange <http://www.midwest-ix.com/> >> <https://www.facebook.com/mdwestix> >> <https://www.linkedin.com/company/midwest-internet-exchange> >> <https://twitter.com/mdwestix> >> The Brothers WISP <http://www.thebrotherswisp.com/> >> <https://www.facebook.com/thebrotherswisp> >> >> >> <https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg> >> ------------------------------ >> >> *From: *"That One Guy /sarcasm" < <[email protected]> >> [email protected]> >> *To: *[email protected] >> *Sent: *Monday, February 1, 2016 3:02:44 PM >> *Subject: *[AFMUG] Packetflux gigabit syncinjector force connectorized >> epmp 24 V >> >> I have a site we will initially feed with an epmp force 110 >> (connectorized epmp) and serve two EPMPgps APs from it. To conserver space, >> I want to just run all three radios off a gigabit syncinjector, but the >> epmp connectorized is limited to 30 v. >> >> Is there any issue running the EPMP gps APs on 24 volts? >> >> >> >> -- >> >> If you only see yourself as part of the team but you don't see your team >> as part of yourself you have already failed as part of the team. >> >> >> > > >