Why not use the the ePMP PtP/AP Lite for an SM? It's not much more than a
regular SM and it
can be powered the same as the APs.

On Mon, Feb 1, 2016 at 4:58 PM, Adam Moffett <[email protected]> wrote:

> If Steve is wondering:  The a lot of Meanwell PSU's have a screw to adjust
> the output voltage.  Usually it's to match the float voltage of batteries,
> but if you don't have batteries you can crank it up all the way.
>
>
>
> On 2/1/2016 4:29 PM, Josh Baird wrote:
>
> We have gone back to sites and cranked the PSU's feeding the SyncInjectors
> up to ~30V.  We had numerous power and sync problems in the cold weather
> when our PSU's were outputting ~25-26V (there was ~150ft of cable to the
> radio as well).  We'll be rolling 48V at all future sites.
>
> On Mon, Feb 1, 2016 at 4:25 PM, Brandon Yuchasz <[email protected]>
> wrote:
>
>> I have run all mine at 24 volts all winter without issue. I did not have
>> any of the cold susceptible mac addresses however. My only concern is if
>> had a long power outage and batteries died perhaps the epmp would have
>> powered up the heaters and never got to boot. It did not happen so it’s
>> simply a theory on what could still go wrong for me this winter. I do plan
>> to step those packetflux units up to 29.5v soon as possible.
>>
>>
>>
>>
>>
>> Best regards,
>>
>> Brandon Yuchasz
>>
>> GogebicRange.net
>>
>> <http://www.gogebicrange.net/>www.gogebicrange.net
>>
>>
>>
>> *From:* Af [mailto:[email protected]] *On Behalf Of *Mike Hammett
>> *Sent:* Monday, February 01, 2016 3:04 PM
>> *To:* [email protected]
>> *Subject:* Re: [AFMUG] Packetflux gigabit syncinjector force
>> connectorized epmp 24 V
>>
>>
>>
>> Running them at 24v is what some of the commotion has been about lately.
>>
>>
>>
>> -----
>> Mike Hammett
>> Intelligent Computing Solutions <http://www.ics-il.com/>
>> <https://www.facebook.com/ICSIL>
>> <https://plus.google.com/+IntelligentComputingSolutionsDeKalb>
>> <https://www.linkedin.com/company/intelligent-computing-solutions>
>> <https://twitter.com/ICSIL>
>> Midwest Internet Exchange <http://www.midwest-ix.com/>
>> <https://www.facebook.com/mdwestix>
>> <https://www.linkedin.com/company/midwest-internet-exchange>
>> <https://twitter.com/mdwestix>
>> The Brothers WISP <http://www.thebrotherswisp.com/>
>> <https://www.facebook.com/thebrotherswisp>
>>
>>
>> <https://www.youtube.com/channel/UCXSdfxQv7SpoRQYNyLwntZg>
>> ------------------------------
>>
>> *From: *"That One Guy /sarcasm" < <[email protected]>
>> [email protected]>
>> *To: *[email protected]
>> *Sent: *Monday, February 1, 2016 3:02:44 PM
>> *Subject: *[AFMUG] Packetflux gigabit syncinjector force connectorized
>> epmp 24        V
>>
>> I have a site we will initially feed with an epmp force 110
>> (connectorized epmp) and serve two EPMPgps APs from it. To conserver space,
>> I want to just run all three radios off a gigabit syncinjector, but the
>> epmp connectorized is limited to 30 v.
>>
>> Is there any issue running the EPMP gps APs on 24 volts?
>>
>>
>>
>> --
>>
>> If you only see yourself as part of the team but you don't see your team
>> as part of yourself you have already failed as part of the team.
>>
>>
>>
>
>
>