Thanks gents
On Mar 26, 2016 10:02 AM, "Jason McKemie" <[email protected]>
wrote:

> I've extended smartjacks a couple hundred feet via existing copper, never
> had any issues.
>
> On Saturday, March 26, 2016, Jaime Solorza <[email protected]>
> wrote:
>
>> A friend of mine callled yesterday and asked me about extending a T-1
>> link from Smart jack to new location.   He is wondering if he can use the
>> existing copper and jump the 4 wires and finish of with 40 ft of Cat5 to
>> new location.
>> If I remember correctly he should end up with 1 volt and run should not
>> exceed 6000 ft.     refresh my memory you oracles of DS-1s
>>
>> Jaime Solorza
>> Wireless Systems Architect
>> 915-861-1390
>>
>

Reply via email to