Power at the CPE side?
What is the CPE and how are you powering it?
Have you tried powering it from a completely different source/outlet?
I know this is fiber but I have seen UBNT power supplies do weird packet loss 
when plugged into an inverter.
I have also seen weird electronic issues when a device was plugged into an 
outlet where the circuit was shared with other electronics.
Or an outlet that was shared with a motor or air compressor and every time the 
motor kicked in it caused problems.







> On May 13, 2016, at 12:46 PM, Sterling Jacobson <sterl...@avative.net> wrote:
> 
> Never seen this before, and my fiber crews are telling me it's impossible.
> 
> But I get intermittent FCS and Internal MAC errors on a fiber line to a house 
> when things get hotter during the day.
> 
> Then at afternoon and all through the night it's fine.
> 
> It's a gradual fade into suckyness with ping loss going from 1,2 -3 percent 
> then almost total ping loss, then fading back from that to no loss again.
> 
> The fiber crew has OTDR shot the line twice, including during the bad fade 
> times and see nothing wrong loss or light wise.
> 
> But I've replaced the electrical components and patch cable three times.
> I've taken the equipment from the side of the house and plugged it into the 
> cabinet and no loss.
> 
> I can't help but feel like there is something wrong with the fiber line, but 
> I've never seen it do anything like this.
> 
> There is construction nearby, but this line is in a conduit and should have 
> been effected by that.
> And what would cause this kind of fade in/out anyway?
> 
> Again, the fiber team says it's fine and swear nothing like this could ever 
> happen with fiber ever.
> 
> Any ideas? Anyone seen this?
> 
> 