Leave power on all 8 wires to the house and switch data on all 8 wires to the test port....the complexity of this problem just hit me. Sounds like more trouble than anybody would want to pay you for.

------ Original Message ------
From: "Adam Moffett" <dmmoff...@gmail.com>
To: af@afmug.com
Sent: 1/9/2017 3:55:24 PM
Subject: Re: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

Sounds like you shouldn't.


------ Original Message ------
From: "Chuck McCown" <ch...@wbmfg.com>
To: af@afmug.com
Sent: 1/9/2017 3:49:57 PM
Subject: Re: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

I have thought about it.

First problem is the 8 pole dual throw switch. They exist but they are physically large and expensive.

Second problem is that 444 segregates data on 4 wires and power on 4 different wires. With GigE ata and power are on all 8 wires.

So, I would have to have some inductors switch into the circuit to block the data from the house when the test port is being used.

Can be done. Not sure if I could do it in that small box. And it would make it considerably more expensive.
Shall I do it?



From:Adam Moffett
Sent: Monday, January 09, 2017 1:44 PM
To:af@afmug.com
Subject: Re: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

Way nicer!

I imagine the 444 would work with a lot of Mikrotik CPE, or cameras, or anything 100BaseT with power on the spare pairs. That probably means a hundred different possible uses to list. *shrug* maybe it doesn't matter and they should just get the gigE unit if they're not sure.

How come there's no test port on the GigE-POE? Seems like if you could tick that one box you could just deprecate the 444.


------ Original Message ------
From: "Chuck McCown" <ch...@wbmfg.com>
To: af@afmug.com
Sent: 1/9/2017 2:17:56 PM
Subject: Re: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

This better?

From:Adam Moffett
Sent: Monday, January 09, 2017 11:55 AM
To:af@afmug.com
Subject: Re: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

I think it's clear enough. The only question that came to mind was I don't know what the Case Style of "PCB Only" means.

One other comment is that nothing actually says we're looking at surge protectors or that they are ethernet surge protectors. That's irrelevant if the chart is displayed in a context where that's obvious.


------ Original Message ------
From: "Chuck McCown" <ch...@wbmfg.com>
To: af@afmug.com
Sent: 1/9/2017 1:02:27 PM
Subject: [AFMUG] Emailing: Surge Suppressor Technical Chart.pdf

How can I improve this?

Reply via email to