Does this tower have an FM radio station located on it?? -sean
On Thu, Jun 15, 2017 at 4:58 PM Jay Weekley <[email protected]> wrote: > At the moment it's two Mimosa radios at one tower and one radio at > another that have the issue. We replaced our Shireen Cat 5 with Shireen > Cat 6 and Shireen connectors and the link negotiation problem seems to > have gotten better but the Netonix still shows cable errors though a > standard cable tester shows continuity and correct pin out. I may > contact Netonix and see if they can give me a clue as to what problem > their unit is detecting. > > Bill Prince wrote: > > Have you just plugged into a laptop or anything besides the Netonix? > > We've had at least one situation with a bad port on a Netonix switch > > that had symptoms similar to this. > > > > bp > > <part15sbs{at}gmail{dot}com> > > > > On 6/15/2017 3:44 PM, Jay Weekley wrote: > >> We tried it on one radio of the four in question. > >> > >> Faisal Imtiaz wrote: > >>> hmm.. sounds like you have some other issue going on ... > >>> > >>> Faisal Imtiaz > >>> Snappy Internet & Telecom > >>> 7266 SW 48 Street > >>> Miami, FL 33155 > >>> Tel: 305 663 5518 x 232 > >>> > >>> Help-desk: (305)663-5518 Option 2 or Email: [email protected] > >>> > >>> ----- Original Message ----- > >>>> From: "CBB - Jay Fuller" <[email protected]> > >>>> To: [email protected] > >>>> Sent: Thursday, June 15, 2017 6:03:05 PM > >>>> Subject: Re: [AFMUG] Netonix/Mimosa compatibility. > >>>> We tried the Mimosa brick and it didn't help but that was prior to > >>>> trying Mimosa's suggestion of moving to Cat6 . We've tried locking > >>>> it to > >>>> 100 meg full duplex and it held a connection but I am not sure if we > >>>> tried 1 gig half. > >>>> > >>>> Faisal Imtiaz wrote: > >>>>> Here is what I would suggest. > >>>>> > >>>>> 1) Use the Mimosa Brick, for testing, and see if that fixes your > >>>>> issue > >>>>> if it does then consider, using a different port or 48VH > >>>>> power etc to see if the > >>>>> issue is on then netonix side. > >>>>> > >>>>> if you still have the same issue with Mimosa Brick then you > >>>>> know the problem is > >>>>> else ware. > >>>>> > >>>>> BWT.. if you lock both sides (Radio & Netonix) to 100meg full > >>>>> duplex or even 1G > >>>>> half duplex do they hold the connection ? > >>>>> > >>>>> Regards. > >>>>> > >>>>> Faisal Imtiaz > >>>>> Snappy Internet & Telecom > >>>>> 7266 SW 48 Street > >>>>> Miami, FL 33155 > >>>>> Tel: 305 663 5518 x 232 > >>>>> > >>>>> Help-desk: (305)663-5518 Option 2 or Email: [email protected] > >>>>> > >>>>> ----- Original Message ----- > >>>>>> From: "CBB - Jay Fuller" <[email protected]> > >>>>>> To: [email protected] > >>>>>> Sent: Thursday, June 15, 2017 5:06:16 PM > >>>>>> Subject: Re: [AFMUG] Netonix/Mimosa compatibility. > >>>>>> Oh, and no surge protector at the moment. > >>>>>> > >>>>>> Faisal Imtiaz wrote: > >>>>>>> have not seen that issue ... > >>>>>>> > >>>>>>> Are you using 48VH port ? or just 48V ? > >>>>>>> and is there a surge protector in the middle ? > >>>>>>> > >>>>>>> Regards > >>>>>>> > >>>>>>> Faisal Imtiaz > >>>>>>> Snappy Internet & Telecom > >>>>>>> 7266 SW 48 Street > >>>>>>> Miami, FL 33155 > >>>>>>> Tel: 305 663 5518 x 232 > >>>>>>> > >>>>>>> Help-desk: (305)663-5518 Option 2 or Email: > >>>>>>> [email protected] > >>>>>>> > >>>>>>> ----- Original Message ----- > >>>>>>>> From: "CBB - Jay Fuller" <[email protected]> > >>>>>>>> To: [email protected] > >>>>>>>> Sent: Thursday, June 15, 2017 4:44:38 PM > >>>>>>>> Subject: [AFMUG] Netonix/Mimosa compatibility. > >>>>>>>> Has anyone experience a compatibility problem when using Mimosa > >>>>>>>> radios > >>>>>>>> with Netonix for power? We've got a problem with gigabit link > >>>>>>>> negotiation issues where link will alternate between a gig and > >>>>>>>> no link. > >>>>>>>> We've upgraded to Cat 6 and are still seeing the issue. > >>>>>>> --- > >>>>>>> This email has been checked for viruses by AVG. > >>>>>>> http://www.avg.com > >> > > > > > >