Does this tower have an FM radio station located on it??

-sean



On Thu, Jun 15, 2017 at 4:58 PM Jay Weekley <[email protected]>
wrote:

> At the moment it's two Mimosa radios at one tower and one radio at
> another that have the issue. We replaced our Shireen Cat 5 with Shireen
> Cat 6 and Shireen connectors and the link negotiation problem seems to
> have gotten better but the Netonix still shows cable errors though a
> standard cable tester shows continuity and correct pin out. I may
> contact Netonix and see if they can give me a clue as to what problem
> their unit is detecting.
>
> Bill Prince wrote:
> > Have you just plugged into a laptop or anything besides the Netonix?
> > We've had at least one situation with a bad port on a Netonix switch
> > that had symptoms similar to this.
> >
> > bp
> > <part15sbs{at}gmail{dot}com>
> >
> > On 6/15/2017 3:44 PM, Jay Weekley wrote:
> >> We tried it on one radio of the four in question.
> >>
> >> Faisal Imtiaz wrote:
> >>> hmm.. sounds like you have some other issue going on ...
> >>>
> >>> Faisal Imtiaz
> >>> Snappy Internet & Telecom
> >>> 7266 SW 48 Street
> >>> Miami, FL 33155
> >>> Tel: 305 663 5518 x 232
> >>>
> >>> Help-desk: (305)663-5518 Option 2 or Email: [email protected]
> >>>
> >>> ----- Original Message -----
> >>>> From: "CBB - Jay Fuller" <[email protected]>
> >>>> To: [email protected]
> >>>> Sent: Thursday, June 15, 2017 6:03:05 PM
> >>>> Subject: Re: [AFMUG] Netonix/Mimosa compatibility.
> >>>> We tried the Mimosa brick and it didn't help but that was prior to
> >>>> trying Mimosa's suggestion of moving to Cat6 . We've tried locking
> >>>> it to
> >>>> 100 meg full duplex and it held a connection but I am not sure if we
> >>>> tried 1 gig half.
> >>>>
> >>>> Faisal Imtiaz wrote:
> >>>>> Here is what I would suggest.
> >>>>>
> >>>>> 1) Use the Mimosa Brick, for testing, and see if that fixes your
> >>>>> issue
> >>>>>      if it does then consider, using a different port or 48VH
> >>>>> power etc to see if the
> >>>>>      issue is on then netonix side.
> >>>>>
> >>>>>      if you still have the same issue with Mimosa Brick then you
> >>>>> know the problem is
> >>>>>      else ware.
> >>>>>
> >>>>> BWT.. if you lock both sides (Radio & Netonix) to 100meg full
> >>>>> duplex  or even 1G
> >>>>> half duplex do they hold the connection ?
> >>>>>
> >>>>> Regards.
> >>>>>
> >>>>> Faisal Imtiaz
> >>>>> Snappy Internet & Telecom
> >>>>> 7266 SW 48 Street
> >>>>> Miami, FL 33155
> >>>>> Tel: 305 663 5518 x 232
> >>>>>
> >>>>> Help-desk: (305)663-5518 Option 2 or Email: [email protected]
> >>>>>
> >>>>> ----- Original Message -----
> >>>>>> From: "CBB - Jay Fuller" <[email protected]>
> >>>>>> To: [email protected]
> >>>>>> Sent: Thursday, June 15, 2017 5:06:16 PM
> >>>>>> Subject: Re: [AFMUG] Netonix/Mimosa compatibility.
> >>>>>> Oh, and no surge protector at the moment.
> >>>>>>
> >>>>>> Faisal Imtiaz wrote:
> >>>>>>> have not seen that issue ...
> >>>>>>>
> >>>>>>> Are you using 48VH port ? or just 48V ?
> >>>>>>> and is there a surge protector in the middle ?
> >>>>>>>
> >>>>>>> Regards
> >>>>>>>
> >>>>>>> Faisal Imtiaz
> >>>>>>> Snappy Internet & Telecom
> >>>>>>> 7266 SW 48 Street
> >>>>>>> Miami, FL 33155
> >>>>>>> Tel: 305 663 5518 x 232
> >>>>>>>
> >>>>>>> Help-desk: (305)663-5518 Option 2 or Email:
> >>>>>>> [email protected]
> >>>>>>>
> >>>>>>> ----- Original Message -----
> >>>>>>>> From: "CBB - Jay Fuller" <[email protected]>
> >>>>>>>> To: [email protected]
> >>>>>>>> Sent: Thursday, June 15, 2017 4:44:38 PM
> >>>>>>>> Subject: [AFMUG] Netonix/Mimosa compatibility.
> >>>>>>>> Has anyone experience a compatibility problem when using Mimosa
> >>>>>>>> radios
> >>>>>>>> with Netonix for power?  We've got a problem with gigabit link
> >>>>>>>> negotiation issues where link will alternate between a gig and
> >>>>>>>> no link.
> >>>>>>>> We've upgraded to Cat 6 and are still seeing the issue.
> >>>>>>> ---
> >>>>>>> This email has been checked for viruses by AVG.
> >>>>>>> http://www.avg.com
> >>
> >
> >
>
>

Reply via email to