If you have good ftb I would match north/south.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Fri, Jul 28, 2017 at 2:31 PM, Jay Weekley <[email protected]> wrote: > 3 90* panels at 90* angles from each other with one side unserved by 2.4. > south 2432 > north 2437 > west 2412 > > Josh Luthman wrote: > >> I don't think channel size changes the rules of sync - you need a 5 MHz >> guard band, time them, face different directions. >> >> If the three APs are each on 120* you should have no problem, though I >> don't believe any of the sectors have good enough ftb to frequency refuse >> (assuming the 5 MHz is the same space as 20 MHz). >> >> If the three APs are using different frequency space with a 5 MHz guard >> band you're fine. >> >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Fri, Jul 28, 2017 at 12:45 PM, Jay Weekley <[email protected] >> <mailto:[email protected]>> wrote: >> >> Are there any sync problems associated with running APs with >> different channel widths with EPMP? For example, if I have a >> tower with 3 access points and 2 are set for 20 MHz wide channels >> and one is set for a 5 MHZ wide channel will that cause problems? >> >> >> >> <http://www.avg.com/email-signature?utm_medium=email&utm_ >> source=link&utm_campaign=sig-email&utm_content=emailclient> >> Virus-free. www.avg.com <http://www.avg.com/email-sign >> ature?utm_medium=email&utm_source=link&utm_campaign=sig- >> email&utm_content=emailclient> >> >> <#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2> >> > >