I'm pushing our infrastructure over to the lighter used NX216 so at least the monitoring offloads. but I have to say, it really pisses a guy off when hardware specs are removed, really pisses the guy off.
weve been running 750 or so through this one, but bandwidth has increased. As best I can tell its not heavy, like 20kpps if I'm understanding the attacked MT correctly. This started with monitoring anomalies, high pings on monitoring devices on the BMU, but no customer impact, now its croaking customer latencies. On Mon, Sep 25, 2017 at 9:15 PM, Adair Winter <[email protected]> wrote: > I think we started having issues around 600 or 800 subs on our NX216 > > > On Mon, Sep 25, 2017 at 9:14 PM, CBB - Jay Fuller < > [email protected]> wrote: > >> >> i have heard rumor you might have problems with a nx216 with 500 or so >> accounts or higher. >> the symptom is when you see "bmu queue" counter start being high(er) on >> your billing server. >> we have not run into this yet and are still on a nx216 - close to 700 >> customers i think. >> >> we have been adding and removing a lot (of customers) lately >> >> >> >> ----- Original Message ----- >> *From:* Steve Jones <[email protected]> >> *To:* [email protected] >> *Sent:* Monday, September 25, 2017 8:47 PM >> *Subject:* [AFMUG] powercode bmu specs >> >> anybody know where the hardware details are? I think we outgrew a bmu, >> but with the whole new nonsense website and haphazard tertiary sites I >> don't seem to be able to find any specs >> >> > > > -- > > Adair Winter > VP, Network Operations / Co-Owner > Amarillo Wireless | 806.316.5071 <(806)%20316-5071> > C: 806.231.7180 <(806)%20231-7180> > http://www.amarillowireless.net > <http://www.amarillowireless.net> > > >