Back?  No.  Never had Mikrotik.  In ancient times it was CentOS, then
ImageStream, then their own.

You'll still need a BMU of sorts for SNMP, monitoring, etc but the duties
of queues/routes/redirect/packet pushing are the bigger demands.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Tue, Sep 26, 2017 at 10:14 AM, Steve Jones <[email protected]>
wrote:

> theyre going back to mikrotiks?
>
> On Tue, Sep 26, 2017 at 9:08 AM, Josh Luthman <[email protected]
> > wrote:
>
>> Mikrotik integrated is starting, I'd wait until that's done and avoid
>> buying an official "BMU".
>>
>>
>> Josh Luthman
>> Office: 937-552-2340 <(937)%20552-2340>
>> Direct: 937-552-2343 <(937)%20552-2343>
>> 1100 Wayne St
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>> Suite 1337
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>> Troy, OH 45373
>> <https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
>>
>> On Mon, Sep 25, 2017 at 10:22 PM, Steve Jones <[email protected]>
>> wrote:
>>
>>> I'm pushing our infrastructure over to the lighter used NX216 so at
>>> least the monitoring offloads. but I have to say, it really pisses a guy
>>> off when hardware specs are removed, really pisses the guy off.
>>>
>>> weve been running 750 or so through this one, but bandwidth has
>>> increased. As best I can tell its not heavy, like 20kpps if I'm
>>> understanding the attacked MT correctly.
>>>
>>> This started with monitoring anomalies, high pings on monitoring devices
>>> on the BMU, but no customer impact, now its croaking customer latencies.
>>>
>>>
>>>
>>>
>>>
>>> On Mon, Sep 25, 2017 at 9:15 PM, Adair Winter <
>>> [email protected]> wrote:
>>>
>>>> I think we started having issues around 600 or 800 subs on our NX216
>>>>
>>>>
>>>> On Mon, Sep 25, 2017 at 9:14 PM, CBB - Jay Fuller <
>>>> [email protected]> wrote:
>>>>
>>>>>
>>>>> i have heard rumor you might have problems with a nx216 with 500 or so
>>>>> accounts or higher.
>>>>> the symptom is when you see "bmu queue" counter start being high(er)
>>>>> on your billing server.
>>>>> we have not run into this yet and are still on a nx216 - close to 700
>>>>> customers i think.
>>>>>
>>>>> we have been adding and removing a lot (of customers) lately
>>>>>
>>>>>
>>>>>
>>>>> ----- Original Message -----
>>>>> *From:* Steve Jones <[email protected]>
>>>>> *To:* [email protected]
>>>>> *Sent:* Monday, September 25, 2017 8:47 PM
>>>>> *Subject:* [AFMUG] powercode bmu specs
>>>>>
>>>>> anybody know where the hardware details are? I think we outgrew a bmu,
>>>>> but with the whole new nonsense website and haphazard tertiary sites I
>>>>> don't seem to be able to find any specs
>>>>>
>>>>>
>>>>
>>>>
>>>> --
>>>>
>>>> Adair Winter
>>>> VP, Network Operations / Co-Owner
>>>> Amarillo Wireless | 806.316.5071 <(806)%20316-5071>
>>>> C: 806.231.7180 <(806)%20231-7180>
>>>> http://www.amarillowireless.net
>>>> <http://www.amarillowireless.net>
>>>>
>>>>
>>>>
>>>
>>
>

Reply via email to