I agree with Nate. I assume that if DHCP requests are getting through to your router there is an ethernet link on the radio. For trouble shooting I have the customer move the cable from the radios power supply to another port on their router or directly to a computer to see if a MAC shows up in the bridging table. You may try lowering the link speed to 10 megabit but I can't remember if that has helped or not.

Nate Burke wrote:
Whenever I've seen similar situations, it's always Ethernet problems, bad cable/connector. Or a bad router. Rarely it's a bad SM. Are the Ethernet stats incrementing errors?

On 12/28/2017 7:11 AM, Christopher Gray wrote:
I have a customer who's PMP100 SM is not showing the customer MAC in the Bridging Table. SM and AP have both been rebooted. I usually see 3x addresses in the Bridging Table, 2x for the radio, and 1x for the customer, but I'm just seeing the 2x radio MACs even though customer DHCP requests are making it through to my router.

This just showed up today, as the customer router stopped getting an IP address (the router sees the request for IP, offers it, but it never binds).

Any ideas for kicking this back into functioning status?



---
This email has been checked for viruses by AVG.
http://www.avg.com