Yeah, that has been asked for.  I can do it but it will be ugly.  

From: George Skorup 
Sent: Friday, February 9, 2018 11:01 AM
To: af@afmug.com 
Subject: Re: [AFMUG] new product question

It would be cool to have 4 single-mode duplex LC couplers in that box too.


On 2/9/2018 9:47 AM, ch...@wbmfg.com wrote:

  I can, just trying to keep cost down.� I am using my regular tower surge 
protector enclosure.� 
  Will have 4 circuits in and 4 circuits out.� 
  �
  From: Dave 
  Sent: Friday, February 9, 2018 8:37 AM
  To: af@afmug.com 
  Subject: Re: [AFMUG] new product question
  �
  What about a single loop on the actual enclosure either at the convergence of 
cables entry or at each connector?
  something like a raised loop large enough to pass 1/4" zip tie and small 
enough at each connector to pass a 1/8" zip

  Dave
  �


  On 02/09/2018 09:30 AM, ch...@wbmfg.com wrote:

    I am making a new tower mount multiple circuit surge protector.
    This one is for multiple higher current DC power circuits/ conductors only.
    �
    Trying to come up with a good way to allow the wires to be secured.
    Right now I have a series of rectangular slots in the PCB so a zip tie can 
be passed down behind the board and back up.� 
    �
    Any better ways?


  -- 


Reply via email to