On Thu, Feb 14, 2008 at 7:13 PM, Jim Wilhite <[EMAIL PROTECTED]> wrote: > I read you are rectifying AC to power a DC relay. If that is the case, > I would go to a higher value cap for the filter. Say about 100 uf or > more.
Ok, and what would be the theory behind this.. I'm somewhat ignorant on some of this stuff. The original schematic of the schematic I am repairing calls for 50 uF but I don't have that value in my junk box but I do have 47. Thanks -- JT Croteau, N1ESE - Manchester, NH (FN42gx) Contest Manager, TARA Skirmish ______________________________________________________________ Our Main Website: http://www.amfone.net AMRadio mailing list Searchable Archives: http://www.mail-archive.com/[email protected]/ List Rules (must read!): http://w5ami.net/amradiofaq.html List Home: http://mailman.qth.net/mailman/listinfo/amradio Help: http://mailman.qth.net/mmfaq.html Post: mailto:[email protected] To unsubscribe, send an email to [EMAIL PROTECTED] with the word unsubscribe in the message body.