On Sat, 30 Sep 2000 20:32:49 +0200, Bernie <[EMAIL PROTECTED]> wrote:
> Something like:
> mode com1 baud=19 parity=n data=8
> should work as initializer for the com-port. I don't have the modem connect
> to this computer so I can't test it, "help mode" will get you more
> information.
> BTW: What does DR-DOS allow as a max for "baud rate"
In OpenDos v7.01, 19200 is max setting for the 'mode' command.
syntax:
mode com1:19200,n,8,1
com1 is then set for 19200, no parity, 8 data bits, and 1 stop bit.
Glenn McCorkle [EMAIL PROTECTED] North Jackson, Ohio, USA
DOS prog. for QV cameras http://www.angelfire.com/id/glenndoom/qvplay.html
Other stuff http:[EMAIL PROTECTED]/
--
Arachne, The Web Browser for DOS
Open the 'DOOR' to the WWW. Keep the 'windows' closed.
Download Arachne for DOS http://browser.arachne.cz/dos/
Visit the Arachne home page http://arachne.cz/