My apologies for posting this twice but the first one went without a
subject line.

Joe and Claire,
I am using SMTP out and POP3 in.

I forgot to remove the encrypted password string from the
emaildaemon.properties file. After that and rerunning the emailstart
with the -u password switch it appears to be ok. my overnight
escalations that run notifications sent out all of the messages.

It seems that no matter what the interval setting in .properties file it
takes more than 30 minutes to reset the email engine. I guess there's a
refresh timer for our Exchange server as well.
Thanks, 


John J. Reiser
Software Development Analyst
Remedy Administrator/Developer
Lockheed Martin - MS2
The star that burns twice as bright burns half as long.
Pay close attention and be illuminated by its brilliance. - paraphrased
by me 
 

-----Original Message-----
From: Action Request System discussion list(ARSList)
[mailto:[EMAIL PROTECTED] On Behalf Of Sanford, Claire
Sent: Wednesday, August 06, 2008 11:31 PM
To: [email protected]
Subject: Re: Email Engine Password reset

Can you log onto the server with the user name that is the email
password owner?  Reset the password in the service then and see if it
works.
 
That has worked for me when they made me change the pw.  The last time
around, we created a password that would be next to impossible to hack,
that they let me have a non-expiring password for the email.  Heck, I
have trouble typing it!
 
Claire

________________________________

From: Action Request System discussion list(ARSList) on behalf of
Reiser, John J
Sent: Wed 8/6/2008 5:53 PM
To: [email protected]
Subject: Email Engine Password reset



Hello Listers,
ARS 6.3 Server
ARS 6.3 AREmail
MS SQL 2000
Windows 2000

Corporate security policy changes have required us to reset the password
for the account that runs AR System Services and the AREMail Engine.

The ARSystem has come back up fine but the email engine is not
processing.
I've changed the Remedy Email service Run As password.
I've changed the AR System Email Mailbox Configuration passwords.
I've run the EmailStart.bat with -s servername and -p password setting
added.
Maybe I did this in the wrong sequence because the email engine will not
send email.

Any help would be appreciated. I tried to place a call with BMC but
there Helpdesk system is down.

Maybe they reset a password too;^>

John J. Reiser
Software Development Analyst
Remedy Administrator/Developer
Lockheed Martin - MS2
The star that burns twice as bright burns half as long.
Pay close attention and be illuminated by its brilliance. - paraphrased
by me


________________________________________________________________________
_______
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org Platinum
Sponsor: www.rmsportal.com ARSlist: "Where the Answers Are"



________________________________________________________________________
_______
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org Platinum
Sponsor: www.rmsportal.com ARSlist: "Where the Answers Are"

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
Platinum Sponsor: www.rmsportal.com ARSlist: "Where the Answers Are"

Reply via email to