Paul Gilmartin wrote: > http://pic.dhe.ibm.com/infocenter/zos/v2r1/topic/ > com.ibm.zos.v2r1.asma400/alcon.htm > Alignment of constants > HLASM Language Reference > SC26-4940-06 > > • On boundaries implicit to the type of constant (see "Implicit > Boundary Alignment" in Table 2) when no length is specified. > > • Alignment can be forced to any boundary by a preceding DS or DC > instruction with a zero duplication factor. This occurs whether or > not the ALIGN option is set. > > But by experiment: > > Loc Object Code Addr1 Addr2 Stmt Source Statement > 000000 00000 00002 1 TINY CSECT > 000000 F1 2 A DC C'1' > 000001 3 B DC 0AL4(2) > 000001 4 C DC 0FL4'3' > 000001 F4 5 D DC C'4' > 6 END > > I guess length specifier overrides 0 duplication factor, which overrides > NOALIGN option. This isn't entirely clear -- should the order of the > sections in the manual make it so?
Good point! I'll pass it on to the relevant authorities :) Best regards, Steve Hobson Je me presse de rire de tout, de peur d'être obligé d'en pleurer Unless stated otherwise above: IBM United Kingdom Limited - Registered in England and Wales with number 741598. Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU