Ok, my channel bank is configured. The signaling is configured for fxsloopstart. The framing is esf. The line is b8zs.
When I plug in a crossover cable from the T100P to the channel bank my T1 line status indicator shows a red light. However if I plug a crossover cable straight from the Dmark (PRI) to the channel bank my T1 line status indicator shows green. So I'm thinking my problem is with either my T100P cards/asterisk or the crossover cable but I don't think it's the crossover cable. Any suggestions on what I should do next or how I can trouble shoot it? On 11 Jul 2003, Steven Critchfield wrote: > On Fri, 2003-07-11 at 08:59, [EMAIL PROTECTED] wrote: > > I have a premisys slimline 24 channel fxs channel bank. I'm attempting to > > get it configured to work with my asterisk server. I have 2 T100P cards > > in the asterisk box. One is connected to an incoming pri, the second is > > connected to the channel bank. > > > > In my /etc/zaptel.conf file I have the line fxoks=25-48 > > In my zapata.conf file I have the line signaling=fxo_ks > > > > When talking to the company I bought the channel bank from, they wish to > > know what type of signaling the channel bank will get. Apparently their > > only familiar with connectling the channel bank straight to the T1 line. > > What type of signalling do I need to advise them that the channel bank is > > receiving? He advised me that they commonly see loopstart signaling. > > When I mentioned Koolstart to him, he was unfamiliar with it. I went with > > fxoks because that is what someone on the list recommended. All > > suggestions are appreciated. > > AJ > > Koolstart is loopstart with disconnect supervision. > _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users