I am connecting my Quad T1 card to the Siemens HIpath 4000 with pri.
Port 1 is working just fine. But port 2 is not working.
I think I have my configuration correct (see below).
Is there something special about configuring 2 PRI? I have done it with
dual T1 no problem.
I am using asterisk 1.2.9.1 libpri-1.2.3 and zaptel 1.2.6.
THanks,
Jerry
------------------
zaptel.conf:
span=1,1,0,esf,b8zs
bchan=1-23
dchan=24
span=1,1,0,esf,b8zs
bchan=25-47
dchan=48
zapata.conf:
signalling=pri_cpe
switchtype=national
echocancel=yes
echocancelwhenbridged=yes
echotraining=400
callerid=asreceived
context=smvoice-incoming
group=1
channel => 1-23
signalling=pri_cpe
switchtype=national
echocancel=yes
echocancelwhenbridged=yes
echotraining=400
callerid=asreceived
context=smvoice-incoming
group=1
channel => 25-47