1) IGC Flight Recorder specifications require pin 1&2 and pin 7&8 on the RJ-45 connector of a IGC compliant cable to be in parallel... http://www.fai.org/gliding/system/files/tech_spec_gnss.pdf#page=32
2) There is no such thing as a "FLARM cable" or "FLARM connector". FLARM has never shipped any assembled cables. Am I missing something? Urs FLARM -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Mike Borgelt Sent: Mittwoch, 19. Mai 2010 18:43 To: Discussion of issues relating to Soaring in Australia. Subject: Re: [Aus-soaring] TECHNICAL ALERT Those of using EWMicrorecorders should be very careful to NEVER plug a FLARM connector into the EW by mistake. The EW has built in reverse polarity protection but the FLARM cable by paralleling pins 1 and 2 and pins 7 and 8 on the connector defeats this. Take care! Damage by this method constitutes misuse and is not covered by warranty. The damage is quite distinctive. Mike Borgelt Instruments - manufacturers of quality soaring instruments since 1978 phone Int'l + 61 746 355784 fax Int'l + 61 746 358796 cellphone Int'l + 61 428 355784 email: [email protected] website: www.borgeltinstruments.com _______________________________________________ Aus-soaring mailing list [email protected] To check or change subscription details, visit: http://lists.internode.on.net/mailman/listinfo/aus-soaring _______________________________________________ Aus-soaring mailing list [email protected] To check or change subscription details, visit: http://lists.internode.on.net/mailman/listinfo/aus-soaring