Hi guys!
Increasing timeout of loading tape has helped. But I've edited sources
and recompiled. I didn't know about Maximum Changer Wait, hope it will
help and it's not necessary to recompile bacula.
On Nov 10, 2014, at 11:22 AM, Kern Sibbald <k...@sibbald.com
<mailto:k...@sibbald.com>> wrote:
There is no need to modify the code. Just modify the bacula-sd.conf
file. It is much easier.
Best regards,
Kern
I think Kern refers to here:
http://www.bacula.org/5.0.x-manuals/en/main/main/Storage_Daemon_Configuratio.html
Maximum Changer Wait = time
This directive specifies the maximum time in seconds for Bacula to
wait for an autochanger to change the volume. If this time is
exceeded, Bacula will invalidate the Volume slot number stored in the
catalog and try again. If no additional changer volumes exist, Bacula
will ask the operator to intervene. The default is 5 minutes.
There are several ‘wait’ / ‘time’ options listed there.
—