Hi guys!
Increasing timeout of loading tape has helped. But I've edited sources and recompiled. I didn't know about Maximum Changer Wait, hope it will help and it's not necessary to recompile bacula.



On Nov 10, 2014, at 11:22 AM, Kern Sibbald <k...@sibbald.com <mailto:k...@sibbald.com>> wrote:

There is no need to modify the code. Just modify the bacula-sd.conf file. It is much easier.

Best regards,
Kern

I think Kern refers to here:

http://www.bacula.org/5.0.x-manuals/en/main/main/Storage_Daemon_Configuratio.html

Maximum Changer Wait = time
This directive specifies the maximum time in seconds for Bacula to wait for an autochanger to change the volume. If this time is exceeded, Bacula will invalidate the Volume slot number stored in the catalog and try again. If no additional changer volumes exist, Bacula will ask the operator to intervene. The default is 5 minutes.

There are several ‘wait’ / ‘time’ options listed there.

—
Dan Langille


------------------------------------------------------------------------------
Comprehensive Server Monitoring with Site24x7.
Monitor 10 servers for $9/Month.
Get alerted through email, SMS, voice calls or mobile push notifications.
Take corrective actions from your mobile device.
http://pubads.g.doubleclick.net/gampad/clk?id=154624111&iu=/4140/ostg.clktrk
_______________________________________________
Bacula-devel mailing list
Bacula-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-devel

Reply via email to