I have read many of the messages connected with this. You will know that a pipe 
is much stronger and more rigid than a solid bar. It can of course be 
strengthened with a non-compressible filling like cement and running a little 
rebar through the cement will make it even more rigid. Several years ago I 
installed a pole for holding up a basketball hoop for my son. It is a four inch 
diameter pipe, well two actually, one inside the other made that way to shorten 
it for shipping. I formed a box 18 inches square and about a foot deep from 
plywood, removed a few patio lock stone bricks and dug a hole to set the box 
into using it to form up cement. The pipe was set into this and the pole filled 
with cement which I tamped down very firmly every few inches as per assembly 
instructions. It stands still, 15 years later. It wants a little paint 
especially where the two pipes fit together, I assume because of the dielectric 
causing some corrosion.

I would think that a four inch heavy sewer like A B S pipe might work equally 
well packed firmly with cement. You could form your 'T' for additional lines 
and it would really hurt to hit with a truck or anything else. this would not 
be a suitable solution though if you wish to remove the pipe when not in use.

Getting the old piece out will be very difficult. I like the cork screw 
solution best, if you can get the beggar to turn you should be able to work it 
up and out. Otherwise it is probably busting up a square of the pavement and 
digging it all out.


  ----- Original Message ----- 
  From: Spiro 
  To: [email protected] 
  Sent: Tuesday, June 23, 2009 2:35 PM
  Subject: [BlindHandyMan] clothes line pole





  Hi,
  I have a ?heavy? metal pipe with a 4 spike cap that is used for a clothes 
  line.
  My neighbor across the drive likes his alcohol consumtion; and he has quie 
  dented another neighbor's fence. He got a big SUV and ran down the pole. 
  It is bigger and heavier than the 2.5 inch in our chain link fence in 
  front.
  But I've not measured it yet.
  Here's what I want to do; check it out and let me know if I'm on the right 
  track.
  There's a pipe in the ground, cemented and flush with the driveway. The 
  pipe with the 4 spike cap, fits down into that. Part of this is broken off 
  into the bigger pipe.
  Somehow I have to get that out.
  I then want to get a piece of the same size, 2ft down and 2ft above ground 
  and cement it. I'd like to then get the same size as the pipe that is in 
  the ground, and cement that. I could then drop the final clothes pole into 
  that and have cement and double piping up to about 4ft and make it more 
  durable and memorable than the one he destroyed by driving 5 feet onto my 
  driveway and breaking it for me.
  Wife says that hang dry is faster, and is obviously cheaper; so I need a 
  very durable solution.
  Wife wants to wimp and drag a solitary standing unit in and out every day.
  Not good enough for me.
  Thoughts, advice, help?
  Thanks



  

[Non-text portions of this message have been removed]

Reply via email to