Hi Dale, I understand what you are trying to do and I'm sure that you could 
probably make it work somehow.  How are you going to get a full length peace of 
angle iron above the existing wiring and plumbing without disconnecting cables 
and water lines?  If you can work this out, maybe you could have the upper 
connections on the triangles pre welded to the top angle iron and still be able 
to work it into place.  This would minimize the number of wholes to be drilled 
at the top of the joist, however their would be a lot of angle iron left to 
drill along the bottom cord.  Drilling angle iron with a hand held drill in a 
22 Inch joist bay is not my idea of fun.  How far below the sub floor do the 
electrical cables pass through the joists?  Could you possibly bolt a full 
length of say 2 Inch, heavy gage channel iron to the top and bottom of both 
sides of each joist and connect them with bolts or threaded rod through pre 
drilled wholes.    

 

Paul Franklin

 

  ----- Original Message ----- 
  From: Dale Leavens 
  To: [email protected] 
  Sent: Sunday, October 04, 2009 10:30 AM
  Subject: Re: [BlindHandyMan] stiffening inadequate floor joists?


    Hi,

  I have considered these solutions, I am really trying to avoid cutting into 
all that electrical.

  I thought though that if I created my own sort of web joists in situ I might 
achieve the same thing. A series of joined triangles on the surface of the 
present joist, maybe on opposite faces of the joist then when jacked up into 
good or at least acceptable alignment then run a bolt through at the bottom so 
that when the jack is removed the joined bridge work of triangles are held 
using the original wood joist as the lower cord and I suppose the upper cord as 
well.

  The tops could be bolted through pre-drilled angle attached to the top of the 
side of the joist but one would have to drill angle iron at the bottom of the 
side I would think to keep them from sliding longitudinally.

  ----- Original Message ----- 
  From: Paul Franklin 
  To: [email protected] 
  Sent: Sunday, October 04, 2009 9:52 AM
  Subject: Re: [BlindHandyMan] stiffening inadequate floor joists?

  Dale, it seems to me that the simplest and most cost effective way to stiffen 
up your floor would be to sister dimension 2 by 8 lumber on to the existing 
rough cut 2 by 8 joists. After jacking and leveling each joist you could glue 
and bolt the dimension 2 by 8 beams to the rough cut joist keeping the bottom 
edges parallel, thus keeping the sub floor baring on the original joist. You 
could relocate heating, plumbing and wiring to a chase along the edges of the 
usable space to preserve head room in the center of the basement. An 
alternative would be to replace the existing joists with an engineered joist 
system with an open web, however engineered joist usually are from 10 to 18 
inches deep, which would compromise your existing head room. 

  ----- Original Message ----- 
  From: Dale Leavens 
  To: [email protected] 
  Sent: Saturday, October 03, 2009 9:41 AM
  Subject: [BlindHandyMan] stiffening inadequate floor joists?

  Hi,

  It is too wet outside to do any work and I am contemplating a problem I have 
had since moving into this old building.

  The original house has floor joists rough sawn but only 2 by 8 on 24 inch 
centers. We have a springy and uneven floor. Some of it is also because at some 
point one of the heating systems required framing in a big cold air return and 
they clearly didn't shore up the floor when cutting that joist, someone long 
since removed all of the cross bracing.

  I don't see sistering or adding joists in the usual way because of plumbing, 
wiring and duct work and I don't want to add more posts and beams. It recently 
struck me though that I could build in place an open web joist, jack things 
temporarily up then fix the lower cord. This lead me to think perhaps a better 
way might be to jack tings up just a little above the desired point then apply 
a web of strap steel to either face of the existing joists on the diagonal. A 
series of 'V's so that the diagonal essentially forms triangles. This would 
allow me to continue to respect wiring.

  More stiffening might be achieved by running a length of angle iron along the 
top inside corner against the floor and the joist and run a bolt through it and 
the straps and similarly at the bottom of the joist, I wonder how much would be 
enough and how much too much. At some point it might be better to fabricate 
individual steel webbed joists and fit them between the originals but then they 
may serve the purpose of lifting the originals which would continue to be 
pulling down after nearly a century.

  Just kicking around ideas. I would like to preserve as much open space there 
as I can.

  I don't have reasonable access to engineering or architectural services.

  [Non-text portions of this message have been removed]

  __________ Information from ESET Smart Security, version of virus signature 
database 4477 (20091002) __________

  The message was checked by ESET Smart Security.

  http://www.eset.com

  __________ Information from ESET Smart Security, version of virus signature 
database 4478 (20091003) __________

  The message was checked by ESET Smart Security.

  http://www.eset.com

  [Non-text portions of this message have been removed]

  [Non-text portions of this message have been removed]



  


  __________ Information from ESET Smart Security, version of virus signature 
database 4478 (20091003) __________

  The message was checked by ESET Smart Security.

  http://www.eset.com



__________ Information from ESET Smart Security, version of virus signature 
database 4479 (20091004) __________

The message was checked by ESET Smart Security.

http://www.eset.com



[Non-text portions of this message have been removed]

Reply via email to