Just a comment or two.  All my quick disconnect fittings came with quarter inch 
pipe threads.  Some places may have them in three eights, maybe just my luck.  
I have been told to use only black pipe on air and gas as galvanized may have 
pieces that flake off and may clog orifices.  Galvanized was originally made 
for water use.  It does tend to clog with calcium over the years quicker than 
copper can.  Anyway for I think we all agree use black iron.
Ron
  ----- Original Message ----- 
  From: Bob Kennedy 
  To: [email protected] 
  Sent: Sunday, November 15, 2009 8:58 PM
  Subject: Re: [BlindHandyMan] Help with air fittings


    
  Sorry to be so late on this one. I have my shop set up with half inch black 
pipe. Galvanized will work as well. What you can do is use a shut off valve in 
the line you are branching to. this keeps the air pressure high where you want 
it. I have a few runs, each one branches off of a T valve. I keep it to half 
inch until I get to where the fitting goes and then have to use a half to 3/8 
reducer. The quick disconnect will thread on to a 3/8 nipple. 

  Not sure about the term they are using there. I guess everything has to have 
a technical name. I have always run my air lines just like plumbing other than 
I don't use black or galvanized pipe for water.

  ----- Original Message ----- 
  From: Dale Leavens 
  To: [email protected] 
  Sent: Saturday, November 14, 2009 7:07 PM
  Subject: [BlindHandyMan] Help with air fittings

  I am looking or some help and information on air fittings probably from some 
of you who hang around mechanics shops.

  I am wanting to set up a bit of a network with a couple of points outside, 
the driveway and the back yard for example and a couple of points at opposite 
ends of my basement. There happens to be a sale at 
  boss tools but I am unfamiliar with some of the terminology.

  There are a couple of 1 to 3 manifolds, one describes an M-style couplings. 
What are m-style couplings?

  I believe I would really prefer some sort of device which would permit me to 
select which part of the network to charge with maybe a ball valve, if these 
have such they don't describe them as such. Just that it seems unnecessary to 
charge yards and yards of hose when I only need one.

  Are you aware of such a device or must I fabricate some sort of panel?

  There will probably be more questions in due course.

  Thanks.