At 08:56 AM 12/26/2008, you wrote:
>The coil springs inside the pump jumped out when I took it
>apart, so I wonder if I have 'em the right way around, and if I'm
>missing any parts. Here's how I'm putting it together:
>
>http://public.mvlan.net/content/Coffee/Equipment/Expobar%20Brewtus%20II/20081226%20-%20Pump%20Problem/info/640/20081226-113902-lx2-40166.jpg

It's hard to say from a picture. but I'd guess the bigger one presses 
the piston towards the pump end. Think about how it works and there's 
likely only one way it goes.

The magnet pulls the piston back allowing a bit of water in front of 
it, then the spring, likely the big one pushes the piston back 
closing off  that access and pushing the water out past what should 
be a 1 way valve.

It's possible the white ring goes on the piston and the soft spring 
holds it there, that might be the one way valve.

Just be careful and make sure you're not breaking anything.

I'm assuming the brass side is the outlet, if not tell me and I'll 
re-think what I said.

Ira 


--~--~---------~--~----~------------~-------~--~----~