It's reverting to 40 because that is the temp in your brew boiler. It is
obviously not heating the water. Check the temp probe wire for shorts. That
seems to be a common fault.

On Tue, Aug 18, 2009 at 8:21 AM, JavaJo <[email protected]> wrote:

>
> I went to make a latte this morning and found my digital temperature
> read out was stuck at 40 degrees. I tried resetting it as per the
> manual but it keeps reverting to 40 degrees.
>
> I just replaced the pressure thingy and my B2 seemed to be working
> great.
>
> I'm totally bummed.
>
> JavaJo
>
> >
>

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/brewtus?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to