In my case, it was a worn-out pump. Do you have vibe or rotary? b Sent from my 8-track deck
On Apr 17, 2013, at 19:10, Jim Ranum <[email protected]> wrote: > Hi guys, > > I’ve had my B2 for about 7 years, replaced several parts over the years and > having a strange problem. When I pull a shot, the normal pre-infusion period > is supposed to be 8 seconds and then the pressure normally pops up to the > customary 9—9.5 bars. During the 8 second period, it usually is about 8 bars. > For a couple months now, when I pull a shot it frequently stays in the > pre-infusion period for about 15 to almost 20 seconds and then pops up to > 9—9.5 for just the last 5—10 seconds. > So what do I need to adjust? > > Thanks for your help. > Best, > Jim > > -- > You received this message because you are subscribed to the Google Groups > "Brewtus" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > To post to this group, send email to [email protected]. > Visit this group at http://groups.google.com/group/brewtus?hl=en. > For more options, visit https://groups.google.com/groups/opt_out. > > -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/brewtus?hl=en. For more options, visit https://groups.google.com/groups/opt_out.