Ahem. "Steam boiler over pressure" Sent from my iPhone
> On Jul 22, 2015, at 14:30, Ben McCafferty <[email protected]> wrote: > > Hi all, > > More parts arrived today. I have new elements in both boilers, new > overtemperature switches on both boilers, new PID thermoprobe, new power > switch. > > When I switch the unit on, everything looks good but the steam boiler > continues heating on up to 2 bar, and then the overpressure relief begins to > blow so I switch the unit off and release some pressure from the steam wand. > I have turned my pressurestat (jaeger) all the way down and no change. Any > further ideas to help me solve this lingering problem? > > Thanks all, > Ben McC > Sent from my iPhone > > -- > You received this message because you are subscribed to the Google Groups > "Brewtus" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > To post to this group, send email to [email protected]. > Visit this group at http://groups.google.com/group/brewtus. > For more options, visit https://groups.google.com/d/optout. -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/brewtus. For more options, visit https://groups.google.com/d/optout.