Ahem. "Steam boiler over pressure"

Sent from my iPhone

> On Jul 22, 2015, at 14:30, Ben McCafferty <[email protected]> wrote:
> 
> Hi all,
> 
> More parts arrived today. I have new elements in both boilers, new 
> overtemperature switches on both boilers, new PID thermoprobe, new power 
> switch.
> 
> When I switch the unit on, everything looks good but the steam boiler 
> continues heating on up to 2 bar, and then the overpressure relief begins to 
> blow so I switch the unit off and release some pressure from the steam wand. 
> I have turned my pressurestat (jaeger) all the way down and no change. Any 
> further ideas to help me solve this lingering problem?
> 
> Thanks all,
> Ben McC
> Sent from my iPhone
> 
> -- 
> You received this message because you are subscribed to the Google Groups 
> "Brewtus" group.
> To unsubscribe from this group and stop receiving emails from it, send an 
> email to [email protected].
> To post to this group, send email to [email protected].
> Visit this group at http://groups.google.com/group/brewtus.
> For more options, visit https://groups.google.com/d/optout.

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send email to [email protected].
Visit this group at http://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.

Reply via email to