Doing a little reading, seems pretty clear that my pressure stat has failed also. Quite a coincidence! Anyway, please send any other thoughts, but I'll order a new p-stat. It's been in there for at least five years; date of manufacture is 9/04 so it was on a shelf for at least 3 years before installation, maybe more. best, bmc
Sent from my apple IIe > On Jul 22, 2015, at 14:44, Ben McCafferty <[email protected]> wrote: > > Ahem. "Steam boiler over pressure" > > Sent from my iPhone > >> On Jul 22, 2015, at 14:30, Ben McCafferty <[email protected]> wrote: >> >> Hi all, >> >> More parts arrived today. I have new elements in both boilers, new >> overtemperature switches on both boilers, new PID thermoprobe, new power >> switch. >> >> When I switch the unit on, everything looks good but the steam boiler >> continues heating on up to 2 bar, and then the overpressure relief begins to >> blow so I switch the unit off and release some pressure from the steam wand. >> I have turned my pressurestat (jaeger) all the way down and no change. Any >> further ideas to help me solve this lingering problem? >> >> Thanks all, >> Ben McC >> Sent from my iPhone >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Brewtus" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected]. >> To post to this group, send email to [email protected]. >> Visit this group at http://groups.google.com/group/brewtus. >> For more options, visit https://groups.google.com/d/optout. -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/brewtus. For more options, visit https://groups.google.com/d/optout.