I have a probable solution for you.

I had the same problem with a Brewtus II.
The original temp probe failed. WLL no longer stocks it and sold me the PID 
upgrade kit.

I could not remove the temp probe. I spent a lot of time and tried many 
tools. 
A local plumber could not remove it. My auto mechanic could not budge it.

I was on the phone several times with WLL.
Nothing worked. Absolutely nothing.
I spoke with Todd Salzman. He assured me they could fix it. They did.

I finally drove up to Rochester from NYC and watched a wonderful repair 
technician Johnny Kemmitz solve the problem.
That was easier for me than shipping it and as a bonus I could watch them 
doing the repair.
He tried to remove it mechanically with tools and failed.

He then let it heat up to operating temperature. Of course since the probe 
is not working, you can't read the temperature.
He let it heat for about 20 minutes.

It then spun out effortlessly.
He said that for a few years Expobar had been using some very aggressive 
thread lock compounds.
Heat works!!!!








-- 