Hi all just had the same issue. I replaced the control board. There is a rely on the old boards and mine was fried.
On Wednesday, February 28, 2018 at 9:50:20 PM UTC-5, Rob K wrote: > So I am taking from all this that the recommended fix for the steam boiler > not refilling issue is to replace that controller box? I've got a B-II > that's been doing this for awhile. I had to open it up tonight because the > high limit switch on the brew boiler tripped earlier this week and I guess I > should get it all working right again. > > On Saturday, October 28, 2017 at 11:00:09 AM UTC-5, BklynJim wrote:My steam > boiler fills when the machine is cold but won't refill once warm. I took the > wire off the water level sensor and it still doesn't fill. Any ideas for what > to check? -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at https://groups.google.com/group/brewtus. For more options, visit https://groups.google.com/d/optout.