The Jaeger is a better pressurestat. Sounds like that's part of the problem

⁣Get BlueMail for Android ​

On Jan 20, 2019, 9:11 AM, at 9:11 AM, wsmckenz <[email protected]> wrote:
>
>
>So, I **think** I need replace my pstat on a BII circa 2007. The
>breaker 
>switch keeps failing. When I reset it, sometimes things work for a few 
>days, but some times the pressure meter just pegs out completely, and
>the 
>brew boiler never comes on.
>
>
>First question, does it sound like pstat is the problem? I already
>replaced 
>the little breaker switch with a new one.
>
>
>Second, I have a jaeger (shown the left). Will it do for a replacement?
>
>
>Finally, for wiring, I think the top white goes to #1 on the Jaeger,
>the 
>bottom white goes to #2 and the red to #4 does this sound right?
>
>
>Cheers,
>
>~Bill
>
>
>
>
>[image: IMG_3663.jpg][image: IMG_3664.jpg]
>
>-- 