Jason,

Did you find the right part? Have same problem with my Office Lever.

On Tuesday, April 2, 2019 at 11:52:26 AM UTC-5, Jason Brechin wrote:
>
> A leak developed where the PTFE tubing brings water from the pump toward 
> the boilers. Going in to part 5 on page 18: 
> https://wiki.wholelattelove.com/images/2/24/BREWTUS_IV_Parts_Diagram.pdf
>
> The diagram has part number 30400020, a 2-piece elbow with a part that 
> screws over the PTFE tube pushed onto a male tip. The part in my machine 
> was a push-to-connect fitting, as shown on WLL (currently out of stock): 
> https://www.wholelattelove.com/products/expobar-elbow-replacement-kit
>
> The tech support suggested that the push-to-connect elbow fitting was the 
> newer part, but mine mechanically failed. After attempting to re-seat the 
> tube, the ring you push in to release the tube fell out/off the elbow. 
>
> While this is carrying "cold" water, it seems to be a "hot" area, 
> conducting a bit of heat from the boiler above. Can this be replaced with 
> any other fitting or type of connection? Do the "old" elbows offer better 
> reliability despite not being push-to-connect? Has anyone replaced this 
> section with braided stainless or other alternatives?
>
> Thanks,
> Jason
>

-- 