Oh yes, I totally hear you! And thanks for all the info, I will try that next. great thing about the brewtus I purchased was that the previous owner had added quite a few upgrades like the flow control and all exterior parts to walnut wood as well as some others which is nice and I'm coming from a Breville Barista Express. I was hoping to get into e61's but wasn't sure if I wanted to go all the way and spend almost 3k for a Bianca or 4k for decent lol But all in all im loving this brewtus. Thanks again and looking forward to this community for sure!
On Tuesday, March 23, 2021 at 6:20:33 PM UTC-5 [email protected] wrote: > Lol. Hey Ben. I can't tell you how many times Ben has helped me when my > Brewt gave trouble! This is a great group even though a lot of us have > moved on to different machines over the years. > > Herman > > > On Tue, Mar 23, 2021 at 7:17 PM 'Ben McCafferty' via Brewtus < > [email protected]> wrote: > >> Good point Herman (and hello!). >> If enough steam is escaping, that could drop the water level in the steam >> boiler and cause the pump to cycle to fill it back up. I mistyped earlier I >> think when I said “brew boiler” for what gets refilled. Listen to Herman, >> he’s smarter than me. ;) >> >> Best, >> b >> >> On Mar 23, 2021, at 16:14, Herman Dickens <[email protected]> wrote: >> >> As Ben said replace the o-ring. If the pump stops and you don't hear the >> hiss that's all you need to do. If you fix the hiss and the pump still >> keeps coming on you have another issue. I've had the o-ring leak cause my >> pump to come on like yours is doing so hopefully that will fix it. >> >> Herman >> >> >> On Tue, Mar 23, 2021 at 6:01 PM Roy <[email protected]> wrote: >> >>> I think it may be this.. I hear a light hiss and im thinking its coming >>> from that area but it also looks as if the safety valve is leaking >>> (lightly) as well. But I am wondering if that is just due to the fact of it >>> doing its job inadvertently because of the vacuum valve. O-ring >>> replacements or just switch out both valves with new ones? Any recs? >>> On Tuesday, March 23, 2021 at 3:07:46 PM UTC-5 [email protected] >>> wrote: >>> >>>> May be that the check valve for the steam is leaking. If so you should >>>> be able to hear it. I think it's called a vacuum relief valve. >>>> >>>> Herman >>>> >>>> >>>> On Tue, Mar 23, 2021 at 4:02 PM Roy Aguilar <[email protected]> wrote: >>>> >>>>> Hello all, so I recently upgraded from a bbe to a expobar brewtus iv >>>>> non rotary, I’ve had this thing for about a week and I’m not much of a >>>>> milk >>>>> drinker so I usually only have brew boiler on but today wife wanted a >>>>> capp >>>>> so I turned on both boilers. This is my first e61 machine and was >>>>> wondering >>>>> if vibration pump comes on intermittently every few minutes for a couple >>>>> of >>>>> seconds is normal. Or am I possibly looking at something to repair in the >>>>> near future? Thanks in advance! >>>>> >>>>> -- >>>>> You received this message because you are subscribed to the Google >>>>> Groups "Brewtus" group. >>>>> To unsubscribe from this group and stop receiving emails from it, send >>>>> an email to [email protected]. >>>>> To view this discussion on the web visit >>>>> https://groups.google.com/d/msgid/brewtus/81f50764-19c0-4d3b-afa8-449f196ebe43n%40googlegroups.com >>>>> >>>>> <https://groups.google.com/d/msgid/brewtus/81f50764-19c0-4d3b-afa8-449f196ebe43n%40googlegroups.com?utm_medium=email&utm_source=footer> >>>>> . >>>>> >>>> >>> -- >>> You received this message because you are subscribed to the Google >>> Groups "Brewtus" group. >>> To unsubscribe from this group and stop receiving emails from it, send >>> an email to [email protected]. >>> To view this discussion on the web visit >>> https://groups.google.com/d/msgid/brewtus/1e5d81c8-4c9f-4adf-9ecc-2808ea8460bbn%40googlegroups.com >>> >>> <https://groups.google.com/d/msgid/brewtus/1e5d81c8-4c9f-4adf-9ecc-2808ea8460bbn%40googlegroups.com?utm_medium=email&utm_source=footer> >>> . >>> >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Brewtus" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected]. >> To view this discussion on the web visit >> https://groups.google.com/d/msgid/brewtus/CAM9mha217k5sg1HJaExpHZa5PGw9DSRGSPqcRqZoP4gTA3yM%2Bw%40mail.gmail.com >> >> <https://groups.google.com/d/msgid/brewtus/CAM9mha217k5sg1HJaExpHZa5PGw9DSRGSPqcRqZoP4gTA3yM%2Bw%40mail.gmail.com?utm_medium=email&utm_source=footer> >> . >> >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Brewtus" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected]. >> > To view this discussion on the web visit >> https://groups.google.com/d/msgid/brewtus/890AE940-693F-43FB-AD8D-13F6FE6597AC%40me.com >> >> <https://groups.google.com/d/msgid/brewtus/890AE940-693F-43FB-AD8D-13F6FE6597AC%40me.com?utm_medium=email&utm_source=footer> >> . >> > -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/11759834-1064-4fd2-aa9c-70ca525502fbn%40googlegroups.com.