oh forgot to ask, but where do you all suggest to get parts from? WLL, 1st, etc? Thanks!
On Tuesday, March 23, 2021 at 6:33:42 PM UTC-5 Roy wrote: > Oh yes, I totally hear you! And thanks for all the info, I will try that > next. great thing about the brewtus I purchased was that the previous owner > had added quite a few upgrades like the flow control and all exterior parts > to walnut wood as well as some others which is nice and I'm coming from a > Breville Barista Express. I was hoping to get into e61's but wasn't sure if > I wanted to go all the way and spend almost 3k for a Bianca or 4k for > decent lol But all in all im loving this brewtus. Thanks again and looking > forward to this community for sure! > > On Tuesday, March 23, 2021 at 6:20:33 PM UTC-5 [email protected] wrote: > >> Lol. Hey Ben. I can't tell you how many times Ben has helped me when my >> Brewt gave trouble! This is a great group even though a lot of us have >> moved on to different machines over the years. >> >> Herman >> >> >> On Tue, Mar 23, 2021 at 7:17 PM 'Ben McCafferty' via Brewtus < >> [email protected]> wrote: >> >>> Good point Herman (and hello!). >>> If enough steam is escaping, that could drop the water level in the >>> steam boiler and cause the pump to cycle to fill it back up. I mistyped >>> earlier I think when I said “brew boiler” for what gets refilled. Listen to >>> Herman, he’s smarter than me. ;) >>> >>> Best, >>> b >>> >>> On Mar 23, 2021, at 16:14, Herman Dickens <[email protected]> wrote: >>> >>> As Ben said replace the o-ring. If the pump stops and you don't hear the >>> hiss that's all you need to do. If you fix the hiss and the pump still >>> keeps coming on you have another issue. I've had the o-ring leak cause my >>> pump to come on like yours is doing so hopefully that will fix it. >>> >>> Herman >>> >>> >>> On Tue, Mar 23, 2021 at 6:01 PM Roy <[email protected]> wrote: >>> >>>> I think it may be this.. I hear a light hiss and im thinking its coming >>>> from that area but it also looks as if the safety valve is leaking >>>> (lightly) as well. But I am wondering if that is just due to the fact of >>>> it >>>> doing its job inadvertently because of the vacuum valve. O-ring >>>> replacements or just switch out both valves with new ones? Any recs? >>>> On Tuesday, March 23, 2021 at 3:07:46 PM UTC-5 [email protected] >>>> wrote: >>>> >>>>> May be that the check valve for the steam is leaking. If so you should >>>>> be able to hear it. I think it's called a vacuum relief valve. >>>>> >>>>> Herman >>>>> >>>>> >>>>> On Tue, Mar 23, 2021 at 4:02 PM Roy Aguilar <[email protected]> >>>>> wrote: >>>>> >>>>>> Hello all, so I recently upgraded from a bbe to a expobar brewtus iv >>>>>> non rotary, I’ve had this thing for about a week and I’m not much of a >>>>>> milk >>>>>> drinker so I usually only have brew boiler on but today wife wanted a >>>>>> capp >>>>>> so I turned on both boilers. This is my first e61 machine and was >>>>>> wondering >>>>>> if vibration pump comes on intermittently every few minutes for a couple >>>>>> of >>>>>> seconds is normal. Or am I possibly looking at something to repair in >>>>>> the >>>>>> near future? Thanks in advance! >>>>>> >>>>>> -- >>>>>> You received this message because you are subscribed to the Google >>>>>> Groups "Brewtus" group. >>>>>> To unsubscribe from this group and stop receiving emails from it, >>>>>> send an email to [email protected]. >>>>>> To view this discussion on the web visit >>>>>> https://groups.google.com/d/msgid/brewtus/81f50764-19c0-4d3b-afa8-449f196ebe43n%40googlegroups.com >>>>>> >>>>>> <https://groups.google.com/d/msgid/brewtus/81f50764-19c0-4d3b-afa8-449f196ebe43n%40googlegroups.com?utm_medium=email&utm_source=footer> >>>>>> . >>>>>> >>>>> >>>> -- >>>> You received this message because you are subscribed to the Google >>>> Groups "Brewtus" group. >>>> To unsubscribe from this group and stop receiving emails from it, send >>>> an email to [email protected]. >>>> To view this discussion on the web visit >>>> https://groups.google.com/d/msgid/brewtus/1e5d81c8-4c9f-4adf-9ecc-2808ea8460bbn%40googlegroups.com >>>> >>>> <https://groups.google.com/d/msgid/brewtus/1e5d81c8-4c9f-4adf-9ecc-2808ea8460bbn%40googlegroups.com?utm_medium=email&utm_source=footer> >>>> . >>>> >>> >>> -- >>> You received this message because you are subscribed to the Google >>> Groups "Brewtus" group. >>> To unsubscribe from this group and stop receiving emails from it, send >>> an email to [email protected]. >>> To view this discussion on the web visit >>> https://groups.google.com/d/msgid/brewtus/CAM9mha217k5sg1HJaExpHZa5PGw9DSRGSPqcRqZoP4gTA3yM%2Bw%40mail.gmail.com >>> >>> <https://groups.google.com/d/msgid/brewtus/CAM9mha217k5sg1HJaExpHZa5PGw9DSRGSPqcRqZoP4gTA3yM%2Bw%40mail.gmail.com?utm_medium=email&utm_source=footer> >>> . >>> >>> >>> -- >>> You received this message because you are subscribed to the Google >>> Groups "Brewtus" group. >>> To unsubscribe from this group and stop receiving emails from it, send >>> an email to [email protected]. >>> >> To view this discussion on the web visit >>> https://groups.google.com/d/msgid/brewtus/890AE940-693F-43FB-AD8D-13F6FE6597AC%40me.com >>> >>> <https://groups.google.com/d/msgid/brewtus/890AE940-693F-43FB-AD8D-13F6FE6597AC%40me.com?utm_medium=email&utm_source=footer> >>> . >>> >> -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/06299af1-7357-4d3a-83e4-63eab0c0b0b4n%40googlegroups.com.
