An update - it seems the longer machine sits idle but powered in the lower the temperature drops. After another 45 min it dropped to 50c…
Sent from my iPhone > On Mar 9, 2022, at 4:10 PM, Andrey Sychev <[email protected]> wrote: > > Hi group. I recently replaced brew boiler heating element on my original > Brewtus 2. With new heating element installed and replaced vibratory pump, > deaerator and OPV I observe the following symptom: when machine is turned on > initially, pump turns on as usual, machine heats up to set 93C temperature. > But then, half an hour later, display suddenly drops into the 70C. What can > be the culprit to check? Thanks > > Sent from my iPhone -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/4B7F24BA-623A-4858-99A4-51E24335CF95%40aol.com.