Could be the PID, or signal from PID to boiler. On Whole Latte Love there is a complete diagnosis of the complete system in their video library.
On Wed, Mar 9, 2022 at 3:41 PM 'Andrey Sychev' via Brewtus < [email protected]> wrote: > An update - it seems the longer machine sits idle but powered in the lower > the temperature drops. After another 45 min it dropped to 50c… > > Sent from my iPhone > > > On Mar 9, 2022, at 4:10 PM, Andrey Sychev <[email protected]> wrote: > > > > Hi group. I recently replaced brew boiler heating element on my > original Brewtus 2. With new heating element installed and replaced > vibratory pump, deaerator and OPV I observe the following symptom: when > machine is turned on initially, pump turns on as usual, machine heats up to > set 93C temperature. But then, half an hour later, display suddenly drops > into the 70C. What can be the culprit to check? Thanks > > > > Sent from my iPhone > > -- > You received this message because you are subscribed to the Google Groups > "Brewtus" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > To view this discussion on the web visit > https://groups.google.com/d/msgid/brewtus/4B7F24BA-623A-4858-99A4-51E24335CF95%40aol.com > . > -- Pitcher [email protected] 225-408-9041 -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/CACn%2BS8HezOZZoDhV__4TZGmnnH7E3N1NsoqmspmPB0Bt8NP-JQ%40mail.gmail.com.