On 9/25/07, dand <[EMAIL PROTECTED]> wrote:
>
> [...] In orice caz, blocurile noi sunt proiectate pentru cutremur asa ca
> ideea ca se prabuseste peste catedrala suna cam a "drob de sare in capul
> copilului"
> Dan G
>


Eu nu sunt specialist, deci nu pot sa ma pronunt in cunostinta de cauza.  Din
ce am citit insa in scrisoarea din 12 martie 2007 adresata
Presedintelui PEde catre ing. Emanuel Necula am inteles ca riscul
exista si este foarte
mare.



Va reamintesc ca ing. Necula este un specialist, este inginer de structura,
si este cel care in anii 2004 si 2005 a asigurat, prin firma proprie de
consultanta, servicii de project management si construction management
dezvoltatorului proiectului "Cathedral Plaza", pana la finalizarea
licitatiei internationale si depunerea partii de structura a proiectului.  Nu
am sa mai insist aici asupra aspectelor penale ce deriva din falsificarea de
catre organizatori a desenelor si documentatiei pregatite de firma d-lui
Necula, recurgerea la fals si incalcarea legii drepturilor de autor fiind
probabil necesare pentru obtinerea autorizatiilor si aprobarilor in vederea
demararii constructiei.



Va invit totusi sa studiati scrisoarea d-lui ing. Necula (
http://euro-fam.org/documents/partaged/pub2007/Actions/architectecathedralebucaresten.pdf),
in special pag. 3-4 (si inceputul pag. 5), unde sunt prezentate in detaliu
motivele de risc seismic.  Astfel, o serie de studii nu au fost niciodata
realizate de catre constructor:



A. The "on site" seismic tests to determine the subsoil seismic
characteristics, especially the frequency of ground motion. Severe damages
can occur if the frequency of the ground motion matches the natural
vibration frequencies of the structures, the shaking response of the
structures being enhanced by the phenomenon called resonance. […]



B. […] The very unstable subsoil conditions were never properly investigated
to ascertain their full impact on the stability of the new tower foundation
system and its impact to the surrounding properties.



C. An improper estimation of the differential settlements within the
property of the new project as well as for the surrounding properties, have
under evaluated the structural effects of these settlements to the new tower
infrastructure and superstructure and the existing structures, including the
Complex of St Joseph Cathedral. […]



D. There was no structural evaluation of the Complex of St. Joseph
Cathedral. […] The existing building structures surrounding the new tower,
built with heavy un-reinforced thick masonry walls will not resist shock
waves or large settlements caused by the new tower.



E. A wind tunnel analysis to determine the dynamic effects of the tower to
the surrounding structures, including the re-distribution of ground snow at
the level of the existing lower roofs, was omitted. […]



F. There was no tridimensional seismic analysis of the new tower structure
taking into account the interaction between the tower infrastructure
(foundation walls, basement slabs, mat foundation, slurry walls, and piles)
and the effect of the multidirectional active and passive pressures against
the surrounding soils supporting the existing buildings in the close
proximity of the tower, caused by multidirectional sways that occur during a
major earthquake. […]



Am prezentat (foarte pe scurt) fragmente din motivele invocate in scrisoarea
ing. Necula, dar sfatuiesc pe cei interesati sa citeasca textul complet.



Asa cum am spus, eu nu sunt specialist, deci pot (si trebuie) doar sa ma
bazez pe opiniile profesionistilor.  Din cate am inteles din scrisoarea
respectiva, dl. ing. Necula este un astfel de profesionist.  Cu siguranta,
sunt pe acest grup persoane avizate si cu pregatirea corespunzatoare care
pot confirma sau infirma seriozitatea motivelor invocate in scrisoare.



----------------------------



Vali

"Noble blood is an accident of fortune; noble actions are the chief mark of
greatness." (Carlo Goldoni)

*"When the power of love overcomes the love of power, the world will know
peace." (Jimi Hendrix)*

*Aboneaza-te la ngo_list <http://groups.yahoo.com/group/ngo_list>: o
alternativa moderata (un pic) la [ngolist]*

*Please consider the environment - do you really need to print this email?*

Raspunde prin e-mail lui