Gayle:

   Another indispensable item for your shack is a
100 W., 50 Ohm dummy load.  MFJ sells one for
about $60 + tax and shipping (MFJ-262B, PL-259
connector) .  This one is convection air cooled and
will take 100 W. for about 10 Sec. continuous and
is DC to 1 GHz 1:1 SWR. Get this one or one like it.

73s,
Gary Sitton, K5AMH
[email protected]

On 4/11/2017 11:32, Larry via BVARC wrote:
Gayle,
What’s your SWR? If you’ve got hi SWR the output fold-back circuitry will reduce output. and you will only see full output in a key-down (CW) mode. Voice has a low duty factor so you would only see a low average power output in that circumstance.
Larry
*From:* Gayle Dotts via BVARC
*Sent:* Saturday, 8 April, 2017 2:17 PM
*To:* BRAZOS VALLEY AMATEUR RADIO CLUB
*Cc:* Gayle Dotts
*Subject:* [BVARC] Power supply

Got a question on pwer supply for my Yaesu FT-920.

The FT-920 manual says: 3.5V DC….Rx(w/signal) @2.5A, Tx (100W) @22.0A. My current power supply is a MFJ-4225MV 25A switching power. Is this MFJ will power the Yaesu but I don’t really see the 100W on output Tx, although the amp meter on the MFJ shows 6-12A while transmitting running low to high on the RF PWR knob on the FT-920. Do I need to increase the power supply?? Please advise.

Thanl you,

Gayle Dotts

KF5LVZ

------------------------------------------------------------------------
_______________________________________________
BVARC mailing list
[email protected]
http://mail.bvarc.org/mailman/listinfo/bvarc_bvarc.org
Message delivered to [email protected]


_______________________________________________
BVARC mailing list
[email protected]
http://mail.bvarc.org/mailman/listinfo/bvarc_bvarc.org
Message delivered to [email protected]


_______________________________________________
BVARC mailing list
[email protected]
http://mail.bvarc.org/mailman/listinfo/bvarc_bvarc.org
Message delivered to [email protected]

Reply via email to