I'm not answering what you asked, but for a new 2nd story install  I will
suggest you put a good deep copper ground rod in the ground directly below
the shack window and run a good copper conductor, I think wide flat
copper braided is best (? is that still the consensus?), and ground all
chassis to that ground.  Being up on the second story can present
RF-in-the-shack problems if you don't have a very good low inductance path
to ground.
ROD / W5IE

Rod Neumann (832)444-0192
ALLogic Inc. / AdorStore
PO Box 217
NEW ULM, TX 78950



On Thu, Feb 22, 2024 at 10:05 AM Chuck via BVARC <bvarc@bvarc.org> wrote:

> Building new house 2 story with radio room upstairs was thinking of
> bringing cables in under the eve near the peek was looking for any advice
> and what type of device with the connectors to buy…..new to ham radio so
> not much experience any help appreciated .
>
>
>
> Chuck Hale
>
> KF5UXP
>
>
> ________________________________________________
> Brazos Valley Amateur Radio Club
>
> BVARC mailing list
> BVARC@bvarc.org