Hi Casper,
[Question]:
Is there a way to ask casper_xps to finish synthesized design and stop there 
(meaning not to attempt placement), and I take over in PlanAhead? This will 
save me a few hours each run. I checked the casper wiki for casper_xps but I'm 
not sure which step corresponds to completion of synthesized design.

[Background]:
We have an X-engine design that is guaranteed not to meet timing in casper_xps 
compiling, but we have found a reliable floor planning strategy (pblocks etc) 
in PlanAhead to make it compile. I have been debugging it thus making minor 
changes that makes no difference as far as compiling is concerned, so it is a 
waste of time in casper_xps to go from a synthesised design to an implemented 
design, given that its implementation will fail timing anyways. (I'm using 
planahead language here, sorry if that's not clear.)

Thank you guys so much!
Jeff