Thanks for the update, Michael!  I'm glad you got it resolved.

Dave

On Aug 10, 2015, at 5:47 AM, Michael D'Cruze wrote:

> Hi guys,
>  
> Just to say that Xilinx came back with a pretty standard response, evidently 
> not reading through my message thoroughly enough. After explaining a second 
> time, the only suggestion they could come back with was to reinstall 
> everything (Matlab, Xilinx ISE etc.) which I’ve now done, and the black 
> boxing seems to be working.
>  
> If anyone comes across this in future….”brute force” reinstallation worked 
> for me. Though I still have no idea what caused the problem in the first 
> place.
>  
> Thanks
> Michael
>  
> From: Homin Jiang [mailto:[email protected]] 
> Sent: 10 August 2015 04:24
> To: Michael D'Cruze
> Subject: [casper] VHDL black-boxing: basic issue
>  
> Hi Michael:
>  
> Which version of toolflow you are using ?
> If V14.7, following is my own solution, hope that help:
>       • Or right click the "black box" on the library icon, then select the 
> VHD file, for example, amiba2_v147/fft_1k_core.vhd. This vhd file has the 
> same name as the one under amiba2_v147/fft_1k_core. Don't get mess up.
>       • copy the *.m file from the subdirectories to upper level. i.e. copy 
> fgain_core_config.m from /amiba2_v147/fgain_core to amiba2_v147. Because the 
> black box only search the config file in the same directory.
>       • Check the " this_block.addFile('vhd')" in the config.m file, it has 
> to be correct vhd filename, for example: "cdelay_core.vhd", not just "vhd". 
> homin jiang
>  
>  
>  
> Message: 4
> Date: Fri, 7 Aug 2015 14:50:41 +0000
> From: "Michael D'Cruze" <[email protected]>
> Subject: [casper] VHDL black-boxing: basic issue
> To: "'[email protected]'" <[email protected]>
> Message-ID:
>         
> <am2pr01mb0385dc4804c6367dcdff39828a...@am2pr01mb0385.eurprd01.prod.exchangelabs.com>
>  
> Content-Type: text/plain; charset="us-ascii"
>  
> Hi Casper,
>  
> I'm trying to black box some of my larger blocks (PFB, FFT), initially 
> following tutorial 6 and the memo on the wiki. Both say that, as soon as the 
> black box is dropped into the model, it should throw up a dialog box allowing 
> me to link to the pre-compiled code. However, this dialog doesn't come up. I 
> can't see any other instances of this on the mail archive... does anyone have 
> any ideas how to solve this, or get the block to manually link to the .vhd 
> file? I can't see anything obvious from within Simulink. This seems a really 
> silly problem!
>  
> Thanks
> Michael
> -------------- next part --------------
> An HTML attachment scrubbed and removed.
> HTML attachments are only available in MIME digests.
>  
> End of casper Digest, Vol 93, Issue 7
> *************************************


Reply via email to