*** For details on how to be removed from this list visit the ***
*** CCP4 home page http://www.ccp4.ac.uk ***
hi
you can use either xprep (from bruker axes) or
reindex (ccp4i) to interchange the hkl to a
conventional space group P21212.
cheers
vk
--- Ethayathulla Abdulsamath
<[EMAIL PROTECTED]> wrote:
> hi all
>
> Actually I am trying to solve a structure in
> orthorhombic system.
> I tried phaser it suggested me a solution in P22121.
> So i tried to interchange cell axis using sftools.
>
> I want to interchange cell axis hkl to lkh.
>
> I tried sftools reindex
>
> where I changed the matrix
>
> 0 0 1
> 0 1 0
> 1 0 0
>
> But it didn't change cell axis.
>
> Then I tried by taking intensities and using sftools
> similarly changing
> the matrix i generated mtz but still it didn't do.
>
> I tried CAD also to reindex by I can't get it right
>
> so plz give me suggestions to interchange hkl to lkh
>
>
> Thanking you
>
> Ethayathulla
>
>
> ###################################################
> A.S.Ethayathulla,Ph.D.
> Department of Biophysics
> All India Institute of Medical Sciences
> Ansari Nagar
> New Delhi-110029
> India.
> ###################################################
>
Kabaleeswaran Venkataraman
Arise, Awake and stop not until goal is Reached
- Swami Vivekanand
__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around