IMO, the GUI is a lifesaver for getting undergraduates involved in
crystallography in an efficient way. While it is possible to teach my
undergraduates to write scripts for CNS, CCP4, and O, it is much, much
easier for them to learn the CCP4 GUI. Sooner or later, real problems
require you to look under the hood to some degree or other, so it is not
so much a black box as one would think, but to the extent that it is, it
has made crystallography accessible to many more investigators and
students than otherwise. (If you had asked me a decade ago if my
undergraduates would be solving protein X-ray structures I may have
laughed.) Personally, I would like to see as many options as possible
included in the GUI, just for consistency and ease of use, although I
realize that this requires a lot more work on the developers' part. But
when all else fails, there is always RTFM...or CCP4BB.
 
Cheers,
___________________________________________ 
Roger S. Rowlett 
Professor 
Department of Chemistry 
Colgate University 
13 Oak Drive 
Hamilton, NY 13346 

tel: (315)-228-7245 
ofc: (315)-228-7395 
fax: (315)-228-7935 
email: [EMAIL PROTECTED] 

        -----Original Message-----
        From: CCP4 bulletin board [mailto:[EMAIL PROTECTED] On
Behalf Of Kolstoe S.E.
        Sent: Thursday, May 10, 2007 5:09 AM
        To: [email protected]
        Subject: Re: [ccp4bb] Refmac and B factors
        
        
        Thanks very much for the replies, and especially for the link to
the previous thread on this topic (Eva).
         
        Just a comment about the ccp4i GUI in general - pretty much all
the students in my department are slowly becoming dependant on the GUI
because it is so much easier to use for those brought up using MS
windows. However, is it really fair to be distributing the GUI as a
"finished" product when it has so many limitations, and in this
particular case is just plain misleading? Although I applaud the idea of
making crystallography more user friendly, is it not just asking for
trouble (and bad science) when software is written that gives the
illusion that things are more straight forward than they actually are?
         
        Simon
         
        
        
________________________________

        From: CCP4 bulletin board [mailto:[EMAIL PROTECTED] On
Behalf Of Eva Kirchner
        Sent: 09 May 2007 17:37
        To: [email protected]
        Subject: Re: [ccp4bb] Refmac and B factors
        
        
        Hi Simon,
        
        you can't stop it - I asked the same question (with some more
questions) some weeks ago. 
        
        You can find the original email and the tips I got for
not-so-good resolution B-factor refinement here:
        http://www.mail-archive.com/[email protected]/msg01224.html
        
        Good luck,
        Eva
        
        
        
        2007/5/9, Kolstoe S.E. <[EMAIL PROTECTED]>: 


                Dear all,
                
                I have a structure at fairly low resolution that I am
trying to refine
                with Refmac. I do not want to refine B factors so have
arbitrarily set
                them all to 20 and then run refmac in the ccp4i GUI
after deselecting 
                the "refine temperature factors" box. However, when I
look at the
                resulting pdb file my B factors vary from 2 to 90.
                
                Is Refmac just calculating my B factors or is it still
refining them,
                and if the latter how can I stop it? 
                
                Thanks,
                
                Simon
                
                


Reply via email to