Hello Eleanor, Thank you very much for your reply. I don't know whether or not the conformation is model biased or not. I just want to make sure the conformation is model free of model bias because these residues are important. The refinement moved the residue back may indicate the previous conformation is correct. I want to know whether there are any other methods to cross-verify the result. Thank you very much for your opinions. Best, Sun
--- On Thu, 7/31/08, Eleanor Dodson <[EMAIL PROTECTED]> wrote: From: Eleanor Dodson <[EMAIL PROTECTED]> Subject: Re: [ccp4bb] question about getting rid of model bias in refinement To: [EMAIL PROTECTED] Date: Thursday, July 31, 2008, 11:41 AM Sun Tang wrote: > Hello Everyone, > > I have a question about getting rid of model bias in refinement with refmac. I solved the structure with molecular replacement. After final refinement of the structure, I found out some key amino acids in the structure and wanted to make sure their conformations are correct. I omitted these amino acids (by setting occupancy to zero) and refined the structure. I manually fit the amino acids into the density and refined the structure again. I found these amino acids return to the precious conformations even though the conformations I fit were different. Should I omit these amino acids from the beginning of the refinement? What is the best way to get rid of the model bias? Your suggestions are greatly appreciated! > > Best, > > Sun > > > > > This seems rather strange! The bias would usually disappear especially if you have a) set occs to 0.0 for selected residues, b) done several cycles of refinement. Could there be 2 conformations for these residues? One where it was originally and one where you have built them? Eleanor