Hi Pengfei, Yes, that's one thing scaling takes care of.
Cheers, Tim On Tue, May 31, 2011 at 02:59:00AM +0800, Pengfei Fang wrote: > Hi Tim, > > I am worry about if there is any problem just scale the two sets together in > HKL2000, since they had different exposure time. > Will the program match them? > > thanks, > Pengfei > > > > > At 2011-05-31 02:50:41,"Tim Gruene" <[email protected]> wrote: > > >Dear pengfei, > > > >you do not need to use mosflm if you want to scale the datasets with scala. > >You > >can use scalepack2mtz (available from ccp4i -> Program List) to convert the > >two > >sca-files to mtz-format and then use scala for scaling. > >Maybe HKL2000/scalepack can scale the files for you if you integrate them > >both > >in the same run (load both data sets, and HKL2000 will integrate both data > >sets). > > > >Tim > > > >On Tue, May 31, 2011 at 02:40:49AM +0800, Pengfei Fang wrote: > >> Hi David, > >> > >> Thanks for your help. I just scaled the two data sets independently using > >> HKL2000. > >> And, I don't know how to set reference in HKL2000 or CCP4. > >> If using CCP4, should I also use imosflm to do integrate? > >> > >> thanks, > >> pengfei > >> > >> > >> At 2011-05-31 02:32:03,"David Veesler" <[email protected]> > >> wrote: > >> Hi Pengfei, > >> you can combine your files using pointless but it is unclear to me based > >> on your message if you have scaled independently the two data sets or not. > >> You should scale these two data sets together using one as reference > >> (doable using XSCALE or SCALA...). > >> Cheers > >> David > >> > >> > >> Le 30 mai 2011 à 11:13, Pengfei Fang a écrit : > >> > >> Dear All, > >> > >> I have two data sets from one crystal. > >> One had short exposures to keep the low resolution reflections from > >> saturating. The other had long exposure to get high resolution data. > >> I am wondering how two merge these two data sets into one file that I can > >> use for refinement. > >> > >> The two sets already scaled by HKL2000. Now I have two .sca files. > >> > >> Thanks a lot! > >> Pengfei Fang > >> > >> > >> > >> -- > >> This message has been scanned for viruses and > >> dangerous content byMailScanner, and is > >> believed to be clean. > >> > >> > >> > >> -- > >> This message has been scanned for viruses and > >> dangerous content byMailScanner, and is > >> believed to be clean. > > > >-- > >-- > >Tim Gruene > >Institut fuer anorganische Chemie > >Tammannstr. 4 > >D-37077 Goettingen > > > >phone: +49 (0)551 39 22149 > > > >GPG Key ID = A46BEE1A > > -- -- Tim Gruene Institut fuer anorganische Chemie Tammannstr. 4 D-37077 Goettingen phone: +49 (0)551 39 22149 GPG Key ID = A46BEE1A
signature.asc
Description: Digital signature
