Shameless self plug:

 

http://scripts.iucr.org/cgi-bin/paper?fw5057

 

That was done with a crappy crystal in a relatively weak beamline. With
a good crystal one can get cleaner data.

 

Cheers.

 

Jose.

========================================
Jose Antonio Cuesta-Seijo, PhD
Carlsberg Laboratory
Gamle Carlsberg Vej 10
DK-1799 Copenhagen V
Denmark

Tlf +45 3327 5332
Email josea.cuesta.se...@carlsberglab.dk
======================================== 

________________________________

From: CCP4 bulletin board [mailto:CCP4BB@JISCMAIL.AC.UK] On Behalf Of
Haytham Wahba
Sent: Tuesday, July 24, 2012 7:14 PM
To: CCP4BB@JISCMAIL.AC.UK
Subject: [ccp4bb] How to identify unknow heavy atom??

 

1- if i have anomalous peak of unknown heavy atom, How can i identify
this heavy atom in general. (different methods)

 

 

2- in my case, i see anomalous peak in heavy atom binding site (without
any soaking). preliminary i did mass spec. i got Zn++ and Cu, How can i
know which one give the anomalous peak in my protein.

 

3- there is way to know if i have Cu+ or Cu++.

 

 

Haytham

UdeM

Biochemistry

Reply via email to