Hi Ian,
 
You are right, here I was too quick. The orthogonal, not the submitted 
coordinates are present in the PDB file. This means that one would indeed need 
to transform the SCALE records and either delete or transform the SMTRY records 
as well. Leaves the question why one would like to store the ORIGX records if 
only the depositor and the PDB annotators ever see the submitted coordinates.
 
Best,
Herman 


________________________________

        From: Ian Tickle [mailto:[email protected]] 
        Sent: Wednesday, March 13, 2013 4:07 PM
        To: Schreuder, Herman R&D/DE
        Cc: [email protected]
        Subject: Re: [ccp4bb] Best practice for transformed PDB coordinates?
        
        

        Hi Herman
        
        
        Yes your solution would also work, and is also safer in the event that 
other programs don't know how to handle SCALE & ORIGX records correctly: you 
are just using ORIGX to store the transformation & leave the co-ordinates alone.
        
        
        I was imagining that James might want to do further work with the 
transformed co-ordinates, so I guess the answer is that it all depends on what 
you plan to do with the file.  As I said, my solution makes the assumption 
(possibly rash!) that the graphics & other programs treat the SCALE & ORIGX 
records correctly.  Actually in my scheme it's only the SCALE records that 
matter (since these are actually what transforms orth -> fract for the symmetry 
to operate on): the ORIGX records are only needed as a reference back to the 
original co-ordinates and can be safely ignored.
        
        
        Cheers
        
        
        -- Ian
        


        On 13 March 2013 14:51, <[email protected]> wrote:
        

                
                Dear Ian,
                 
                As I see it, there is no need to change the orthogonal 
coordinates. They are used in connection with the SYMTRY records to generate 
the symmetry mates. Changing the orthogonal coordinates would mean changing the 
SYMTRY records, which would only complicate things. If we do not change the 
orthogonal coordinates, we do not need to change the SCALE matrix and the only 
thing we need to change is the ORIGX matrix. 
                 
                Since the ORIGX matrix is defined as the matrix transforming 
the orthogonal to submitted coordinates, this is exactly the superposition 
matrix used to transform the original orthogonal coordinates to get these 
submitted coordinates.
                 
                Please correct me if I am wrong!
                Herman


________________________________

                        From: CCP4 bulletin board 
[mailto:[email protected]] On Behalf Of Ian Tickle
                        Sent: Wednesday, March 13, 2013 3:33 PM
                        To: [email protected]
                        Subject: Re: [ccp4bb] Best practice for transformed PDB 
coordinates?
                        
                        
                        Hi James
                        
                        
                        First off, welcome to CCP4BB!
                        
                        
                        I think a bit of matrix algebra solves your problem.
                        
                        
                        Define for the original PDB file:
                        
                        
                        Xf = SoXo  (SCALE transformation orth -> fract).
                        
                        Xs = OoXo (ORIGX orth -> submitted)
                        
                        
                        where upper case means matrix or vector, lower case 
(subscript) identifies different entities.
                        

                        Then for the transformed PDB file:
                        

                        Xt = TXo (orth -> transformed orth)
                        
                        Xf = StXt (transformed orth -> frac)
                        
                        Xs = OtXt (transformed orth -> submitted)
                        
                        
                        To summarise we have:
                        
                        
                        Xf = SoXo = StXt = StTXo
                        
                        Xs = OoXo = OtXt = OtTXo
                        
                        
                        so finally we have:
                        
                        
                        St = SoT^-1
                        
                        Ot = OoT^-1
                        
                        
                        This gives the new SCALE & ORIGX matrices.  Note that 
matrices will need to be homogeneous (4x4) if translations are involved!
                        

                        Sorry email (at least plain text email - HTML email 
would look a lot nicer) is not an ideal medium for matrix algebra!
                        
                        
                        Unfortunately I can't promise that the graphics & other 
programs will treat the new SCALE & ORIGX records correctly - if not complain 
to the authors!  Most likely is that they will simply ignore the SCALE & ORIGX 
records and display the transformed co-ordinates which then obviously won't be 
consistent with the crystallographic symmetry.
                        

                        HTH
                        
                        
                        -- Ian
                        

                        On 13 March 2013 12:57, James Davidson 
<[email protected]> wrote:
                        

                                Dear All,

                                 

                                This is my first post to the group - so 
"Hello"!  I have searched with not much success to find an answer to my 
question, so I thought I would try posting here for some expert advice.

                                I should start by saying that I am not a 
crystallographer, but please don't hold that against me!

                                 

                                I am working with PDB files that are being 
aligned to reference structures, indirectly by (a) using the alignment tools in 
PyMOL, then (b) extracting the transformation matrix and re-applying this to 
the ATOM / HETATM entries outside of PyMOL (to avoid atom reordering / atom 
charging / etc that occurs when directly exporting from PyMOL).  Anyway, what I 
wanted to know is is there a way that I could (or should?) reference that the 
PDB file coordinates have been transformed?  Is there a way of preserving the 
ability of tools (eg PyMOL) to legitimately recreate the symmetry mates from 
the transformed coordinates if I eg apply the same transform to some of the 
data in CRYST1 and SCALE1, SCALE2, SCALE3?  Or should I instead be adding 
ORIGX1, ORIGX2, ORIGX3 entries to show that a transformation has been applied?  
Or, indeed, should I just accept that my aligned coordinates should no longer 
be expected to recreate the packing environment?

                                 

                                I have read through what I think is the correct 
section of the PDB documentation, but I must confess that my lack of expertise 
means I am in danger of approaching an old(?) problem through naïve trial and 
error!

                                 

                                Any help / advice greatly appreciated.

                                 

                                Kind regards

                                 

                                James


                                
______________________________________________________________________
                                PLEASE READ: This email is confidential and may 
be privileged. It is intended for the named addressee(s) only and access to it 
by anyone else is unauthorised. If you are not an addressee, any disclosure or 
copying of the contents of this email or any action taken (or not taken) in 
reliance on it is unauthorised and may be unlawful. If you have received this 
email in error, please notify the sender or [email protected]. Email is 
not a secure method of communication and the Company cannot accept 
responsibility for the accuracy or completeness of this message or any 
attachment(s). Please check this email for virus infection for which the 
Company accepts no responsibility. If verification of this email is sought then 
please request a hard copy. Unless otherwise stated, any views or opinions 
presented are solely those of the author and do not represent those of the 
Company.
                                
                                The Vernalis Group of Companies
                                100 Berkshire Place
                                Wharfedale Road
                                Winnersh, Berkshire
                                RG41 5RD, England
                                Tel: +44 (0)118 938 0000 
<tel:%2B44%20%280%29118%20938%200000> 
                                
                                To access trading company registration and 
address details, please go to the Vernalis website at www.vernalis.com and 
click on the "Company address and registration details" link at the bottom of 
the page..
                                