On 08/20/2017 12:12 PM, Brent Hilpert via cctalk wrote:

> If the transformer were faulty and heating up internally, it would seem 
> unlikely that it would cool off that quickly to recover, IME it takes some 
> time for a transformer to cool off.

I have an open-frame linear PSU that started behaving that way.  Turned
out to be a current-sense resistor with a bad internal connection.  As
things warmed up, the resistance would rise until the current overload
IC kicked it and shut things down.   It was pretty frustrating because
the entire time, the output looked pretty stable.

I don't know if that's what's going on here, however.

--Chuck