The ground was the problem.  For some CRAZY reason, pin 5 of
the 9-pin serial connector of the KA630-AA and cabinet kit
has a 1K Ohm resistance to system ground.
I don't doubt that you had a problem with ground, but on a MicroVAX
console port, Pin 5 is not ground.  Ground is Pin 7.

There are pinout similarities with a PC DE9 serial port, but AFAIK
it's not intentional.

   1: Protective Ground
   2: Transmited Data
   3: Received Data
   4: Request To Send (RTS)
   5: Data Terminal Ready (DTR)
   6: Data Set Ready (DSR)
   7: Signal Ground
   8: Shorted to pin 9 on MicroVAX and VAXstation 2000...
   9:    ...series systems, otherwise left floating.

Ah HA!  This is different than the PC convention!  I will have to make up another cable.  Hmm, I wonder if grounding DTR is responsible for the ?24 UNXINT error during POST?

Thanks,

Jon