On Sun, Aug 2, 2026 at 8:44 PM Jon Elson via cctalk
<[email protected]> wrote:
> The ground was the problem.  For some CRAZY reason, pin 5 of
> the 9-pin serial connector of the KA630-AA and cabinet kit
> has a 1K Ohm resistance to system ground.

I don't doubt that you had a problem with ground, but on a MicroVAX
console port, Pin 5 is not ground.  Ground is Pin 7.

There are pinout similarities with a PC DE9 serial port, but AFAIK
it's not intentional.

  1: Protective Ground
  2: Transmited Data
  3: Received Data
  4: Request To Send (RTS)
  5: Data Terminal Ready (DTR)
  6: Data Set Ready (DSR)
  7: Signal Ground
  8: Shorted to pin 9 on MicroVAX and VAXstation 2000...
  9:    ...series systems, otherwise left floating.

 BCC08 cable has 8-9 shorted because it was the standard console cable
back when "real" serial ports were on DB25s.  I forget which machines
actually use it to detect if a serial console is attached.

-ethan